Champion pp-3 Manual Do Utilizador
C O N T R O L P A N E L S
Hold Temperature
This setting sets the water temperature for the Hold or Clean state.
Parameter name: H O L D T E M P E R A T U R E
Allowed values: 1 0 0
Allowed values: 1 0 0
˚
F
to 1 2 5
˚
F
or 3 8
˚
C
to 5 2
˚
C
Factory default: 1 1 5
˚
F
Soap Minimum
This is the time setting used to set how long the soap pump will run when the soap usage is
set for the minimum amount.
set for the minimum amount.
Parameter name: S O A P M I N I M U M
Allowed values: 0 : 0 0 to 9 . 5 9
Factory default: 0 : 3 0
Allowed values: 0 : 0 0 to 9 . 5 9
Factory default: 0 : 3 0
Soap Intermediate
This is the time setting used to set how long the soap pump will run when the soap usage is
set for the intermediate amount.
set for the intermediate amount.
Parameter name: S O A P I N T E R M E D I A T E
Allowed values: 0 : 0 0 to 9 . 5 9
Factory default: 0 : 4 0
Allowed values: 0 : 0 0 to 9 . 5 9
Factory default: 0 : 4 0
Soap Maximum
This is the time setting used to set how long the soap pump will run when the soap usage is
set for the maximum amount.
set for the maximum amount.
Parameter name: S O A P M A X I M U M
Allowed values: 0 : 0 0 to 9 . 5 9
Factory default: 0 : 5 0
Allowed values: 0 : 0 0 to 9 . 5 9
Factory default: 0 : 5 0
Sanitize Soap
This is the time setting used to set how long the sanitize soap pump will run.
Parameter name: S O A P 2 T I M E
Allowed values: 0 : 0 0 to 9 . 5 9
Factory default: 0 : 0 0
Allowed values: 0 : 0 0 to 9 . 5 9
Factory default: 0 : 0 0
39