Champion pp-3 ユーザーズマニュアル

ページ / 67
C O N T R O L   P A N E L S  
 
Hold Temperature 
This setting sets the water temperature for the Hold or Clean state. 
Parameter name: H O L D   T E M P E R A T U R E  
Allowed values: 1 0 0
˚
F
 
to 1 2 5
˚
F
 or 3 8
˚
C
 to 5 2
˚
C  
 
Factory default: 1 1 5
˚
F
  
Soap Minimum 
This is the time setting used to set how long the soap pump will run when the soap usage is 
set for the minimum amount. 
Parameter name: S O A P   M I N I M U M  
Allowed values: 0 : 0 0   to 9 . 5 9      
Factory default: 0 : 3 0  
 
Soap Intermediate 
This is the time setting used to set how long the soap pump will run when the soap usage is 
set for the intermediate amount. 
Parameter name: S O A P   I N T E R M E D I A T E  
Allowed values: 0 : 0 0   to 9 . 5 9  
Factory default: 0 : 4 0  
 
Soap Maximum 
This is the time setting used to set how long the soap pump will run when the soap usage is 
set for the maximum amount. 
Parameter name: S O A P   M A X I M U M  
Allowed values: 0 : 0 0  to 9 . 5 9  
Factory default: 0 : 5 0  
 
Sanitize Soap 
This is the time setting used to set how long the sanitize soap pump will run.  
Parameter name: S O A P   2   T I M E  
Allowed values: 0 : 0 0   to 9 . 5 9  
Factory default: 0 : 0 0  