Dry Fire Threshold
This is the maximum allowed temperature that heater sheath can attain. When this is
reached, the control assumes the tank has been drained and goes to the Power-up state.
reached, the control assumes the tank has been drained and goes to the Power-up state.
Parameter name: D R Y F I R E T H R E S H O L D
Allowed values: 1 2 5
Allowed values: 1 2 5
˚
F
to 8 5 0
˚
F
or 5 2
˚
C
to 4 5 4
˚
C
Factory default: 2 8 0
˚
F
Change Water Time
This is the maximum time the washer will operate before forcing water to be changed by the
user. The only way to clear the C H A N G E W A T E R message is to empty the tank. Note
that if this time reaches its maximum value during a cycle, the cycle will be allowed to finish.
user. The only way to clear the C H A N G E W A T E R message is to empty the tank. Note
that if this time reaches its maximum value during a cycle, the cycle will be allowed to finish.
Parameter name: C H A N G E W A T E R T I M E
Allowed values: 0 : 0 0 to 9 . 5 9
Factory default: 2 . 0 0
Allowed values: 0 : 0 0 to 9 . 5 9
Factory default: 2 . 0 0
Drain Time
This is the time for how long the drain valve will be opened when the user requests an Auto-
Drain/Fill or Manual Drain.
Drain/Fill or Manual Drain.
Parameter name: D R A I N T I M E
Allowed values: 0 : 0 0 to 9 . 5 9
Factory default: 0 : 1 0 seconds
Allowed values: 0 : 0 0 to 9 . 5 9
Factory default: 0 : 1 0 seconds
Fill Time
This is the time the fill valve will be turned on when the user requests an Auto-Drain/Fill.
Parameter name: F I L L T I M E
Allowed values: 0 : 0 0 to 9 . 5 9
Factory default: 0 : 1 0 seconds
Allowed values: 0 : 0 0 to 9 . 5 9
Factory default: 0 : 1 0 seconds