Champion pp-3 ユーザーズマニュアル

ページ / 67
C O N T R O L   P A N E L S  
 
Dry Fire Threshold 
This is the maximum allowed temperature that heater sheath can attain.  When this is 
reached, the control assumes the tank has been drained and goes to the Power-up state.   
Parameter name: D R Y   F I R E   T H R E S H O L D  
Allowed values: 1 2 5
˚
F
 to 8 5 0
˚
F
 or 5 2
˚
C
 to 4 5 4
˚
C
 
Factory default: 2 8 0
˚
F  
 
Change Water Time 
This is the maximum time the washer will operate before forcing water to be changed by the 
user.  The only way to clear the C H A N G E   W A T E R  message is to empty the tank.  Note 
that if this time reaches its maximum value during a cycle, the cycle will be allowed to finish. 
Parameter name: C H A N G E   W A T E R   T I M E  
Allowed values: 0 : 0 0  to 9 . 5 9  
Factory default: 2 . 0 0  
 
Drain Time 
This is the time for how long the drain valve will be opened when the user requests an Auto-
Drain/Fill or Manual Drain. 
Parameter name: D R A I N   T I M E  
Allowed values: 0 : 0 0  to 9 . 5 9  
Factory default: 0 : 1 0   seconds 
 
Fill Time 
This is the time the fill valve will be turned on when the user requests an Auto-Drain/Fill. 
Parameter name: F I L L   T I M E  
Allowed values: 0 : 0 0  to 9 . 5 9  
Factory default: 0 : 1 0    seconds 
This is the last parameter of the low-level programming, and pressing Stop after this one will 
cause the unit to go back to the Power-up state. 
41