WAN Configuration Using Local Management
CSX200 Family User’s Guide
145
d.
Use the arrow keys to highlight CCP Enable. Press the SPACEBAR to select ON, if you 
want data compression enabled or OFF, if you do not, then press ENTER.
5.
Use the arrow keys to highlight the SAVE command, then press ENTER. The message “Save 
Done!” displays and Local Management saves the changes to memory.
The WAN configuration is complete. It takes up to 60 seconds for the WAN Interface to come out 
of standby and for communications to begin.
Fractional T1 Configuration Using PPP
This section provides step-by-step instructions for configuring the CSX200 to use a fractional T1 
circuit in a PPP environment. This example assumes the setup shown in 
 using two 
CSX200s. Configurations may vary depending on the devices used. In a fractional T1 setup, only a 
portion of the 24 Time Slots or DS-0s are used.
Figure 69
 
Fractional T1  Configuration
NOTE
Upon saving this screen, the interface just configured is assigned to an application 
port (PT#) in the table on the right hand side of the screen.
NOTE
The terms DS-0 (Digital Signal, level 0) and Time Slot are used synonymously in this 
guide to represent a standard 64,000 bit/second channel.
SITE #1
CSX200
SITE #2
CSX200
Telco Cloud
16 Time Slots
16 Time Slots
1482_06