Enterasys csx200 Guia Do Utilizador

Página de 261
WAN Configuration Using Local Management
148
CSX200 Family User’s Guide
d.
Use the arrow keys to highlight CCP Enable. Press the SPACEBAR to select ON, if you 
want data compression enabled or OFF, if you do not, then press ENTER.
4.
If the T1 Line Coding is AMI on the previous screen:
a.
Use the arrow keys to highlight Line Coding. Press the SPACEBAR to select INV-HDLC
then press ENTER.
b.
Use the arrow keys to highlight Active Protocol. Press the SPACEBAR to select PPP, then 
press ENTER.
c.
Use the arrow keys to highlight PPP Type. Press the SPACEBAR to select BNCP, then 
press ENTER.
d.
Use the arrow keys to highlight CCP Enable. Press the SPACEBAR to select ON, if you 
want data compression enabled or OFF, if you do not, then press ENTER.
5.
Use the arrow keys to highlight the SAVE command, then press ENTER. The message “Save 
Done!” displays and Local Management saves the changes to memory.
The WAN configuration is complete. It takes up to 60 seconds for the WAN Interface to come out 
of standby and for communications to begin.
Frame Relay Configuration
This section provides step-by-step instructions for configuring the CSX200 to use a T1 circuit in a 
Frame Relay environment. This example assumes the setup shown in 
CSX200s. Configurations may vary depending on the devices used.
Figure 70
 
Frame Relay Configuration
NOTE
Upon saving this screen, the interface just configured is assigned to an application 
port (PT#) in the table on the right hand side of the screen.
SITE #1
Telco Cloud
24 Time Slots
24 Time Slots
SITE #2