U-Line clrco2175b40 Guia Do Utilizador

Página de 28
8
CLR2160, CLRCO2175
Final Water/Drain Connection
1. Connect the water supply fitting by screwing the brass 
garden hose fitting to the watervalve in the rear of 
the unit.
2. Tighten this fitting with pliers.
Note: Do not use Teflon tape or joint compound on this 
fitting. The rubber washer provides an adequate seal. 
Other materials could cause blockage of the valve.
Figure 12
3. Attach the copper water line to the back of the unit 
using the supplied clamp and the back panel screw 
(Figure 12, CLR2175 model shown). This will prevent 
rotation of the line when moving the unit.
4. Plug in the unit and put unit into OFF mode by holding 
the power key for 10 seconds. Not doing this will cause 
the unit to fill with water for 3 minutes.
5. Turn on the water supply and ensure the connections 
are free of leaks.
6. Begin to push the appliance into the desired cabinet 
opening. The copper tubing should remain in 2 coils 
behind the unit.
IMPORTANT
IMPORTANT
Normal operation creates some vibration. A water 
supply line contacting cabinet wall may cause 
excessive noise during operation or damage to the 
line.
7. While pushing the unit into the opening, continuously 
reroute the drain tube to avoid kinks. The most 
common installation pulls the slack into an adjacent 
cabinet or basement area. 
8. If installing a gravity drain, ensure you provide proper 
slope.
9. After unit is in its final position, finish routing drain 
tube to the desired location. Common installations use 
a floor drain, standpipe, garbage disposal, or Y-branch 
tailpiece type drain connection (Figures 89 and 10).
10. Check to ensure unit is level both side to side and front 
to back. See Leveling on Page 16
IMPORTANT
IMPORTANT
For the gravity/floor drain or the standpipe be sure 
to secure the drain line to these items to prevent it 
from coming loose and causing water damage.
IMPORTANT
IMPORTANT
For disposer or Y-branch tailpiece connections press 
the drain tube over the barbed end of the connector 
and secure with a worm clamp. Make sure the 
knockout inside the tailpiece has been removed for 
both types of connections. Depending on the size of 
the Y-branch or disposer fitting, an adapter may be 
necessary to interface between the 5/8” hose and 
connection.
11. Turn the unit to the on position by holding the power 
key for 10 seconds.
12. Pour 1 gallon of water into the ice bin and check all 
connections for leaks. Ensure the water is flowing from 
the bin. If the water does not flow from the bin there 
may be an issue with the drain connection, such as kinks 
or improper slope. If your unit has a drain pump, an 
indicator of P1 on the display will alert you of a slow or 
clogged drain.
13. If any issues are found, retrace the drain connection, 
correct the issue and retest with water.
Proced to Electrical Specifications.
ULIN_S_0166b1_A