Factory-Installed Drain Pump
If your drain line will run up to a stand pipe, disposal 
assembly or spigot assembly or does not otherwise meet 
the requirements for a Gravity Drain, you may have 
ordered the CLR2160 or CLRCO2175 with a U-Line P60 
Drain Pump. See Figures 89 and 10 for typical 
installations requiring a Drain Pump. If you need to install 
a P60 Drain Pump into your unit, see Locally-Installed 
Drain Pump
 on Page 6.
IMPORTANT
IMPORTANT
Before installing your U-Line CLR2160 or CLRCO2175 
with Factory-Installed U-Line P60 Pump, it is 
extremely important to check and test all hose 
connections at the drain pump. There is a possibility 
that hose connections may have loosened during 
shipment.
To check and test hose connections:
1. Make certain the unit is not plugged into an electrical 
outlet.
2. Carefully push the power cord grommet through the 
hole in the back panel (Figure 6, CLRCO2175 shown).
Figure 6
3. Remove 12 screws and back panel.
WARNING
Back panel serves as a guard. DO NOT put your 
hands inside the ice maker cabinet or attempt to 
touch any components except the discharge tube 
during testing. Failure to follow this warning 
could result in serious personal injury or death.
4. Check that the clamps and hose connections are tight at 
the following areas (Figure 7):
• Discharge tube (A)
• Drain tube (B)
• Vent tube (C)
Figure 7
5. Place a suitable container beneath the pump’s discharge 
tube. (The bucket must be able to hold a minimum of 
one gallon.)
6. Plug the ice maker power cord into a properly 
grounded, polarized electrical outlet.
7. Place the unit into OFF mode by holding power key for 
10 seconds. Not doing this will cause the unit to start 
the fill cycle which will run for 3 minutes.
8. Verify pump operation by pouring one gallon of water 
into the ice storage bin of the ice maker. The pump 
should energize and pump the water into the container.
9. At this time, verify that all tube and clamp connections 
are tight and leak-free. 
10. Unplug unit power cord from electrical outlet.
11. Reinstall back panel.
Locally-Installed Drain Pump
If a gravity drain connection is not possible, and you have 
not purchased a CLR2160 or CLRCO2175 with factory-
installed pump, we strongly recommend the use of the 
U-Line P60 drain pump. The U-Line P60 drain pump is 
available through your Dealer, with complete installation 
instructions. If a pump other than the U-Line P60 drain 
pump is to be used, it must meet the following 
specifications:
• It must be UL listed and have a UL listed, 120 VAC, 
3-wire grounded power cord.
• It must have overall maximum outside dimensions of 
8-3/4" wide x 5-3/4" deep x 7-3/4" high.
• It must have a minimum flow rate of 1.5 gallons per 
minute at 10 feet of lift.
• It must have a sealed sump which does not allow water 
leakage in the case of a power outage, restricted drain 
or pump failure.
Power
Cord
Grommet
Drain
Fitting
Back
Panel
Water
Connection
Screws
ULIN_0574_A
Back View
Side View
B
B
A
C
C
ULIN_0575_A