ZyXEL p-334 Manual Do Utilizador

Página de 366
Prestige 334 User’s Guide
287
Chapter 30 Firmware and Configuration File Maintenance
The following table is a summary. Please note that the internal filename refers to the filename 
on the Prestige and the external filename refers to the filename not on the Prestige, that is, on 
your computer, local network or FTP site and so the name (but not the extension) may vary. 
After uploading new firmware, see the ZyNOS F/W Version field in Menu 24.2.1 – System 
Maintenance – Information
 to confirm that you have uploaded the correct firmware version. 
The AT command is the command you enter after you press “y” when prompted in the SMT 
menu to go into debug mode. 
30.2  Backup Configuration
Option 5 from Menu 24 – System Maintenance allows you to backup the current Prestige 
configuration to your computer. Backup is highly recommended once your Prestige is 
functioning properly. FTP is the preferred methods for backing up your current configuration 
to your computer since they are faster. 
Please note that terms “download” and “upload” are relative to the computer. Download 
means to transfer from the Prestige to the computer, while upload means from your computer 
to the Prestige.
30.2.1  Backup Configuration
Follow the instructions as shown in the next screen. 
Table 96   Filename Conventions
FILE TYPE
INTERNAL NAME
EXTERNAL NAME
DESCRIPTION
Configuration 
File
Rom-0
This is the configuration filename on the 
Prestige. Uploading the rom-0 file replaces 
the entire ROM file system, including your 
Prestige configurations, system-related data 
(including the default password), the error 
log and the trace log.
*.rom
Firmware
Ras
This is the generic name for the ZyNOS 
firmware on the Prestige.
*.bin