Follow the procedure below to configure your P-660HWP-Dx to be managed by CNM 
Access. See the Command Interpreter appendix for information on the command structure and 
how to access the CLI (Command Line Interface) on the P-660HWP-Dx. 
"
In this example a.b.c.d is the IP address of CNM Access. You must change 
this value to reflect your actual management server IP address or domain 
name. See 
 for detailed descriptions of the commands.
Figure 144   Enabling TR-069 
The following table gives a description of TR-069 commands. 
ras> wan tr069 load
ras> wan tr069 acsUrl a.b.c.d
Auto-Configuration Server URL: http://a.b.c.d
ras> wan tr069 periodicEnable 1
ras> wan tr069 informInterval 2400
TR069 Informinterval 2400
ras> wan tr069 active 1
ras> wan tr069 save
Table 105   TR-069 Commands
ROOT
COMMAND OR 
SUBDIRECTO
RY
COMMAND
DESCRIPTION
wan
tr069
All TR-069 related commands must be preceded by wan tr069.
load
Start configuring TR-069 on your P-660HWP-Dx.
active [0:no/
1:yes]
Enable/disable TR-069 operation. 
acsUrl <URL>
Set the IP address or domain name of CNM Access. 
username 
[maxlength:15]
Username used to authenticate the device when making a 
connection to CNM Access. This username is set up on the server 
and must be provided by the CNM Access administrator.
password 
[maxlength:15]
Password used to authenticate the device when making a 
connection to CNM Access. This password is set up on the server 
and must be provided by the CNM Access administrator.
periodicEnable 
[0:Disable/
1:Enable]
Whether or not the device must periodically send information to 
CNM Access. It is recommended to set this value to 1 in order for 
the P-660HWP-Dx to send information to CNM Access.
informInterval 
[sec]
The duration in seconds of the interval for which the device MUST 
attempt to connect with CNM Access to send information and 
check for configuration updates. Enter a value between 30 and 
2147483647 seconds. 
save