Viking Range vdsc530-4b Guia De Especificação

Página de 7
COOKING
Professional Custom Series Freestanding Dual Fuel
Self-Clean 30”/36”W. Sealed Burner Electronic Control Range
P L A N N I N G A N D D E S I G N G U I D E
V I K I N G R A N G E . C O M
1 - 8 8 8 - V I K I N G 1
R E V I S E D 3 / 2 9 / 1 0
© 2 0 1 0 V R C — I N F O R M AT I O N S U B J E C T T O C H A N G E
2”
(5.1 cm)
Dia.
2-3/4”
(7.0 cm)
4-3/8”
(11.1 cm)
2-1/2”
(6.4 cm)
1-3/4”
(4.4 cm)
31-1/16”
(78.9 cm)
28-5/16”
(71.9 cm)
23-7/16”
(59.5 cm)
Gas or electrical
connection in
this area
Gas connection
in this area
Installation Requirements
ACCESS REQUIREMENTS
Note: Ground plug and electrical wire toward the direction of the electrical outlet.
VDSC530T-4B
VDSC536T-6B
VDSC536T-4G
VDSC536T-4Q
Surface burner rating
Surface burners
15,000 BTU Nat. (4.4 kW)/
15,000 BTU Nat. (4.4 kW)/
15,000 BTU Nat. (4.4 kW)/
15,000 BTU Nat. (4.4 kW)/
12,500 BTU LP (3.7 kW)
12,500 BTU LP (3.7 kW)
12,500 BTU LP (3.7 kW)
12,500 BTU LP (3.7 kW)
Surface burners
18,500 BTU Nat. (5.4 kW)/
18,500 BTU Nat. (5.4 kW)/
(front right)
16,600 BTU LP (4.9 kW)
16,600 BTU LP (4.9 kW)
One griddle
15,000 BTU Nat. (4.4 kW)/
12,500 BTU LP (3.7 kW)
One grill
18,000 BTU Nat. (5.3 kW)/
16,000 BTU LP (4.7 kW)
UTILITY
REQUIREMENTS
GAS
• Shipped natural or LP/Propane gas;
field convertible with conversion kit
(purchased separately)
• Accepts standard residential 1/2”
(1.3 cm) ID gas service line
• Gas manifold pressure
o Natural gas 5.0” W.C.P.
o LP/Propane 10.0” W.C.P.
ELECTRICAL
• Electrical connection box on product
for hardwire direct; connect with
locally supplied 3-wire, flexible cord
rated or “pigtail” rated 40 amp 125-
250 VAC min.; must be agency-
approved for use with household
electric ranges.
• Check your national and local codes
regarding this unit.
• Maximum amp usage—
240 – 208 VAC/
60 Hz
o 4B
• 240V—25.4 amps
• 208V—22.9 amps
o 6B/4G/4Q
• 240V—28.5 amps
• 208V—24.7 amps
PLUMBING
Not applicable