Viking Range vgsc366-4g Instrução De Instalação

Página de 20
2
ELECTRICAL GROUNDING INSTRUCTIONS
This range must be electrically grounded in
accordance with local codes, or in the absence of
local codes, with the National Electrical Codes,
ANSI/NFPA 70-latest edition.   This appliance is
equipped with a three-prong plug for your
protection against shock hazard and should be
plugged directly into a properly grounded
receptacle.  Do not cut or remove the grounding
prong from this plug.  Do not connect product to
GFI circuit.  The minimum of 102VAC is required for
proper operation of gas ignition systems.  Prior to
servicing, disconnect appliance electrical supply.
For sealed top units the power disconnect is
located behind the lower access panel.  This
should only be removed by a qualified service
technician.
FOR PERSONAL SAFETY, THIS APPLIANCE MUST
BE PROPERLY GROUNDED
GENERAL INFORMATION
•WARNING:  The use of cabinets for storage above the
appliance may result in a potential burn hazard.
Combustible items may ignite, metallic items may become
hot and cause burns.  If a cabinet storage is to be provided
the risk can be reduced by installing a rangehood that
projects horizontally a minimum of 5” (12.7 cm) beyond the
bottom of the cabinets.
•WARNING:  This appliance shall not be used for space
heating.  This information is based on safety
considerations.
•All openings in the wall behind the appliance and in the
floor under the appliance shall be sealed.
•Keep appliance area clear and free from combustible
materials, gasoline, and other flammable vapors.
•Do not obstruct the flow of combustion and ventilation air.
•Disconnect the electrical supply to the appliance before
servicing.   The power disconnect for the sealed top
units is located behind the lower access panel of the
range.  This should only be removed by a qualified
service technician.
•When removing oven for cleaning and/or service;
A.  Shut off gas at main supply
B.  Disconnect AC power supply
C.  Disconnect gas line to the inlet pipe.
D.  Carefully remove the range by pulling outward.
•Electrical Requirement
Listed on Specification sheet.  Electrical installation should
comply with national and local codes.
•Gas Manifold Pressure:
Natural gas 5.0” W.C.P.
LP/Propane 10.0” W.C.P.
•Flexible Connections:
If this unit is to be installed with flexible couplings and/or
quick disconnect fittings, the installer must use a flexible
connector of at least 1/2” ID (1.3 cm) NPT with suitable
strain reliefs and comply with ANSI Z21.41 and Z21.69
standards.
•The misuse of oven doors (e.g. stepping, sitting, or leaning
on them) can result in potential hazards and/or injuries.
LEGS
•Legs are packed in styrofoam top pack.
•Legs should be installed near to where the appliance is to
be used, as they are not secure for long transit.  After
unpacking the range, raise it about a foot to remove the
bottom shipping skid.  Keep the unit raised to permit the
legs to be screwed into our couplings and lower it gently
to keep any undue strain from the legs and internal
mounting hardware.  It is strongly recommended that a
pallete or lift jack be used rather than tilting.
NOTE:  If legs are removed from range and range rests on a
combustible surface, warranty and AGA/CGA
certification are void.
WARNING
BACK TRIM ACCESSORIES
Assembly and installation instructions are included
with all back trim accessories.