Kent Euroclean 152 Guia Do Utilizador

Página de 17
FORM NO. 56041490 / DuraVac
 152 - 8
OPERATING THE MACHINE
1
To release the Power Cord (12) from the Cord Hooks (2), press the
Handle Lock Button (4) in while pushing down on the Handle (1) and
pull  the  power  cord  off  the  hooks.    Plug  the  Power  Cord  into  a
properly grounded electrical outlet.
2
Turn the Main Power Switch (17) ON.  “l” is ON and “O” is OFF.
3
Step on the Pedal (11) and tilt the handle back.  The Green Light (8)
on the base will come on to indicate that the brush motor is running.
C - IMPORTANT !
Foot pedal must be used to release base to operating position.
Failure  to  do  so  could  result  in  damage  to  the  handle  release
mechanism.
4
Turn the Height Adjustment Knob (10) to adjust the height of the
brush.  If the Red Light (7) comes on, slowly turn the Knob in the
opposite direction until the light goes off.
If the red light stays on continuously, there may be debris wrapped
around the brush.  This can cause the overload protector for the
brush motor to trip.  If this occurs, turn the Main Switch OFF and
unplug the power cord.  Remove any debris from the brush and turn
the Main Switch back ON.  This will automatically reset the overload
protector. The machine can also be reset by locking the handle in
the upright position.  Remove any debris from the brush and repeat
Step 3.  If the overload protector trips repeatedly, or if the red light
stays on continuously, contact Kent for service.
5
Change the bag whenever the “Bag Full” Light (15) comes on.
If the light comes on before the bag is full, the inside of the bag may
be coated with very fine dust (change the bag), or debris may be
built up somewhere between the brush and the bag.
USING THE WAND
To use the Wand (13), put the Handle in the upright locked position.  The
brush motor will stop automatically.  Slide the Wand out of its holder.
Install the Crevice Tool (14) or Dusting Brush (22) on the end of the
Wand, if desired.
AFTER USING THE MACHINE
1
Unplug the Power Cord from the electrical outlet and wrap it around
the Cord Hooks on the front of the machine.
2
Check to see if the bag is full, replace if necessary.  Clean the bag
housing, if necessary.
3
Clean or replace the Vacuum Inlet Filter every third time the bag is
changed.  Clean or replace the Electrostat Exhaust Filter every fifth
time the bag is changed.
4
Remove any built-up carpet fibers or debris from the brush housing.
5
Store the machine indoors in a clean, dry place.
VACUUM MOTOR BRUSHES
Have your Kent Dealer check the carbon motor brushes once a year or
after 500 operating hours.
IMPORTANT !
Motor damage resulting from failure to service the carbon brushes
is not covered under warranty.  See the Limited Warranty State-
ment.
MAINTENANCE
CAUTION !
Always disconnect the Power Cord before performing any ma-
chine maintenance.
CHANGING THE PAPER DUST BAG
Change the Bag whenever the “Bag Full” Light comes on.  To replace the
Paper Dust Bag :
1
Push the Bag Housing Latch (16) in and remove the back cover.
2
Remove the Paper Dust Bag following the instructions printed on
the bag.
3
Install a new Paper Dust Bag following the instructions printed on
the bag.
IMPORTANT !
Never operate the machine without a Dust Bag in place.
CHANGING THE CLOTH DUST BAG
Empty the Bag whenever the “Bag Full” Light comes on.  To empty the
Cloth Dust Bag :
1
Push the Bag Housing Latch (16) in and remove the back cover.
2
Remove the Cloth Dust Bag following the instructions printed on the
bag.
3
Remove bag clip and shake out  bag contents.
4
Put the bag clip back on the bag.
5
Install the Cloth Dust Bag following the instructions printed on the
bag.
6
Replace the Electrostat Exhaust Filter every fifth time the bag is
changed (more often in very dusty applications).
IMPORTANT !
Never operate the machine without a Dust Bag in place.