Nortel 4134 Instrução De Instalação

Página de 102
Internal hardware components
39
Port
Connector
Recommended
cable type
Minimum
cable length
Maximum
cable length
(full duplex),
1000Base-T (full
duplex)
EIA Category
5 UTP or STP
required for
100/1000 Mb/s
operation.
Table 23
Module LEDs
LED
Description
10/100/1000
BASE-T PORT
STATUS
LEDs are integrated into each port.
Status of each interface:
Off: Link not connected or Link Fail
Solid Green: Link established at 10 or 100 Mbps
Solid Orange: Link established at 1000 Mbps
Blinking Green/Orange: Receiving/transmitting traffic
SFP PORT
STATUS
LEDs are integrated into each port.
Status of each interface:
Off: Link not connected or Link Fail
Solid Orange: Link established at 1000 Mbps
Blinking Orange: Receive/transmit traffic
Internal hardware components
There are three internal hardware components that you can service or
upgrade:
DDR SO-DIMM
VPN/IPSec module
Internal system compact flash
The following figure shows the internal hardware components that are field
serviceable. For information about locating and removing the service panel
to access the internal hardware components, refer to Nortel Secure Router
4134 Installation — Chassis (NN47263-300).
Nortel Secure Router 4134
Installation — Hardware Components
NN47263-301
01.02
Standard
10.0
7 August 2007
Copyright © 2007, Nortel Networks
.