Citel 1000 Manual Suplementar

Página de 1
070707 
 
           
 Copyright 2007 Citel plc All Rights Reserved 
 
 
 
EXTender LED Status 
 
This document briefly explains the Front Panel LED status of the PBXgateway and EXTender.  A more 
detailed explanation of these states along with details of the LAN port LED’s can be found in the System 
Administrator’s Guide included with your unit or download from our website 
www.citel.com
 
 
LED 
COLOR STATE 
MENU 
STATE 
EXPLANATION 
PWR 
Solid Red 
ALERT 
DRAM Test Failed. Contact Citel Tech Support. 
 
Solid Yellow 
ALERT 
Self-Test Diagnostic Failure.  Attempt a reboot – power 
cycle.  If LED persists, please contact Citel Tech Support. 
 
Solid Green 
ON 
Normal Operation. 
 
 
 
 
WAN 1 & 2 
Blank – Dark 
DISABLED  Respective WAN port is presently disabled in the UI menu. 
 
Solid Red 
DOWN 
No connection to CSU.  Check cabling.  Please use the 
cable provided with the EXTender unit.  This is a DB25 
straight through Male to Female DTE to DCE cable:      
RS-530. 
 
Solid Yellow 
READY 
CSU UP but the WAN link is not ACTIVE.  Check CSU 
setting for loopback.  No loopback should be enabled. 
 
Solid Green 
UP 
CSU UP but the WAN link is not ACTIVE.  Check the T1 
channel/port mapping and timing on CSU.  Verify that the 
WAN port and CSU on the distant end are configured the 
same. 
 
Slow Green Flash (1x) 
ACTIVE 
Respective WAN port is ACTIVE.  The connection to the 
other unit is alive and phones are extended. 
 
Fast Green Flash (2x) 
TEST 
Respective WAN port is in TEST Mode. 
 
 
 
 
WAN 3 
Blank – Dark 
N/A 
Analog card not available or disabled in menu. 
Remote part 
Solid Yellow 
ONHOOK 
Analog card is enabled and ready. 
#’s with z 
Flashing Yellow 
RINGING 
Analog line is ringing. 
E-6000z-RUM 
Solid Green 
#OFFHK 
Analog line is off hook and in use. 
 
 
 
 
PORTS 
Blank – Dark 
XX 
Port is disabled in menu. 
 
Flickering Green 
NC 
Port is enabled but no connection to local equipment (PBX 
or Phone).  Check all wiring / cables.  This is a local issue. 
 
Solid Green 
RD 
Port is enabled and has continuity to local equipment (PBX 
or Phone) but not extended. Verify connect error / network. 
 
Slow Green Flash (1x) 
UP 
Port is extended and on hook. 
 
Fast Green Flash (2x) 
VC 
Port is extended and off hook. 
 
 
 
 
 
 
 
For Further Assistance, Please Contact Citel Technical Support @ 1-877-248-3587