Citel 6000 Guia Do Utilizador

Página de 281
 
PBXgateway
™ 
& EXTender
TM
 
6000 System Administrator’s Guide
 
84
 
 
System Parameters - Remote Only 
1.  Access the System Menu from the Main Menu using the following path: 
 
Path: Remote->Configuration->System 
 
The following menu appears: 
 
Figure 37:  Gateway Time Offset - Remote System Menu 
2. Select 
Use Gateway Time. When enabled  [Yes], the EXTender will use the PBXgateway 
time to stamp all logging once connected to the PBXgateway. 
 
3.  Enter a value the represents the time difference between the Remote and the 
PBXgateway. This is used to compensate for a time difference between cities. For example 
the Gateway is at a corporate office in Boston and the Remote is in Calgary. Set the value 
to -2. A call made from Boston to Calgary at 10:00am central time will show up as 8:00am 
mountain time. This will ensure that the time stamp on logs as well as the time appearing 
on your phone set will be correct. 
 
4. Press 
the 
↓ key to the Console Baud parameter. Press the → key to modify the setting. 
Note: The <Default> setting is 9600. 
 
5. Press 
the 
→ key to the Modem Init String. This is the AT Command used to initialize the 
modem. 
 
6. Press 
the 
← key to accept changes and go back to the Configuration Menu.  
 
7. Press 
the 
← key to the Save parameter.  
 
8.  Press Enter to save changes to the active config (.rmt) file.