1.  Attach hose firmly with included assembly wrench,
which is magnetized and located on the bottom of the
unit (figure #1). Assemble and attach hose hanger rod
set (figure #2). For “H” series models, there will be no
hose attachment or rod set to attach. 
2.  Using supplied funnel, add a maximum of four quarts
of warm (fresh tap or distilled) water (cold water takes
longer to preheat). Do not overfill. Plug into proper
voltage outlet, turn switch to “PREHEAT”. Steamer
will hold at this temperature, and the light will go off
and on occasionally. NOTE: The J-4000 Steamer
contains a large water reservoir for 2 hours of
continuous steaming. Leave the switch in the
“PREHEAT” position (figure #3) if you plan to use
your steamer throughout the day. This will maintain
water temperature in the reservoir.
3.  Immediately after water is preheated, (red pilot light turns off)  turn switch to
“STEAM” position for steam in approximately 2 minutes. The combined
touch of the steaming head and the direct steam is very important. Some
articles can be steamed better from the underneath side. Always steam with
hose in upright position so any condensation is free to flow back into
steamer. If steaming in a low position near floor, straighten hose up and out
frequently to keep it clear of condensation. If steamer runs
dry it will temporarily shut off. Once finished using the
unit, turn the switch to the “OFF” position. If more water
needs to be added to the steamer, allow steamer to cool
before removing fill cap and adding more water. Never
pour cold water on a hot element. Resume
steaming by resetting the switch to the
“STEAM” position.  
4.  Hang steam head and hose in upright position in the hose
hanger section (figure #4), turn switch to the “OFF” position
(figure #3) and unplug the cord set when not in use.
5.  Periodically, pour old water out of steamer to avoid sediment
build up and maintain proper water level. Never have more
than 4 quarts of water in steamer. If overfilled, water will boil
up into hose. The Jiffy
®
Liquid Cleaner is recommended every 6 months to
flush mineral deposits. See page 29 for complete cleaning instructions.
Every Jiffy
®
Steamer has been factory tested and it is not uncommon for small amounts of
water to be in the unit.
WARNING: Never operate without water. Unplug after each use.
23
Jiffy
®
J-4000 Directions
J-4000
Figure 1
Figure 2
Figure 3
Figure  4