The Power-up Sequence
21
Checking for Correct
Operation of LEDs
During the Power On Self Test, all ports on the Switch are disabled and 
the LEDs light in a rapid sequence.
When the POST has completed, check the Power/Self Test LED to make 
sure that your Switch is operating correctly. 
 shows possible colors 
for the LED.
Table 7   Power/Self Test LED Colors
If there is evidence of a problem, see 
Connecting a
Redundant Power
System
You can connect a SuperStack 3 Advanced Redundant Power System to 
the Switch. This unit, which is also known as an RPS, is designed to 
maintain the power to your Switch if a power supply failure occurs.
For normal redundancy, the unit requires one Type 3 Power Module (part 
number 3C16075).
For full redundancy, the unit requires two Type 3 Power Modules 
combined using a Type 3 Y-Cable (part number 3C16077).
WARNING: If you are connecting the Switch 4900 SX to a Type 3 Power 
Module, read the Safety information section in the Type 3 Power Module 
User Guide.
CAUTION: The Switch can only use a SuperStack Advanced Redundant 
Power System output. 
CAUTION: The Switch has no ON/OFF switch; the only method of 
connecting or disconnecting mains power is by connecting or 
disconnecting the power cord.
Color
State
Green
The Switch is powered-up and operating normally.
Yellow
The Switch has failed its Power On Self Test. This occurs if any of 
the ports fail during power-up.
Off
The Switch is not receiving power.