Table 9   Problems with hardware
*To Power Cycle the unit: Remove and reconnect the AC mains supply. If the unit has no AC 
mains supply, remove and reconnect the DC RPS supply. 
For Technical Support information, see 
Managing the 
Switch
Your Switch can operate in its default state. However, to make full use of 
the features offered by the Switch, and to change and monitor the way it 
works, you have to access the management software that resides on the 
Switch. This is known as managing the Switch.
Managing the Switch can help you to improve the efficiency of the 
Switch and therefore the overall performance of your network. 
There are several different methods of accessing the management 
software to manage a Switch. These methods are explained in 
.
Problem
Suggested Solution
An expansion module 
is installed and the 
unit will not power up
Ensure that the expansion module is fully seated in the 
slot and the connectors are engaged so that the securing 
screws can be tightened.
An SNMP fan fail trap 
is received 
Power off the unit.
Check that the air vents are not obstructed.
Power up the unit.
If a further fan fail trap is received, return the unit.
Unit fails, no SNMP fan 
fail trap is received
Power cycle the unit.*
Check the command line interface to determine 
whether a thermal shutdown has occurred.
If no, return the unit.
If yes, check that: 
The air vents are not obstructed.
The ambient temperature and environmental 
conditions meet those specified in 
Power cycle the unit. If a further thermal shutdown 
occurs, and all environmental conditions are 
satisfactory, return the unit.