Xerox 8000AP Manual Suplementar
C
ALIBRATION
44
15 After you hear a beep or see the dialog background color change, slide the ES-1000 at a slow
but consistent pace across the strip.
Allow about five seconds to slide the length of the strip.
16 Release the button when all the patches in the strip have been measured and you reach the
white space at the end of the strip.
When a strip is measured successfully, the dialog background color changes to green, and the
cross hair moves to the next color. If the strip is not measured successfully, the dialog
background color changes to red, and a message directs you to try again.
cross hair moves to the next color. If the strip is not measured successfully, the dialog
background color changes to red, and a message directs you to try again.
17 Repeat steps
through
until all the strips are measured.
N
OTE
:
You must measure in the order outlined in the Status field.
18 When all the patches have been read successfully, click Accept.
19 Click Apply in the Calibrator dialog box.
The new calibration measurement is applied.
20 Click OK in the Information dialog box.
This completes the Fiery EX8000AP calibration process.