Following are short descriptions of standard built-in 
FP+ Series protection features:
CPL
, (Current Peak Limiter) ensures that the 
amplifier’s  output  does  not  exceed  the  safe 
current handling parameters of amplifier com-
ponents.  
Temperature  protection
  ensures  that  the 
amplifier  will  not  be  damaged  by  exceeding 
thermal limits. 
PAL
, (Power Average Limiter) limits the maximum 
average power consumption according to the 
power supply and mains-breaker capabilities. 
Vhf
, (Very High Frequency) protection circuits 
mute  the  output  of  the  amplifier  when  non-
dynamic continuous signals above 10 kHz are 
detected. 
dC protection
 ensures destructive DC signals 
will not appear at the amplifier outputs. If such 
conditions occur an internal fuse opens and fault 
indication is displayed. 
Low-impedance
 (short circuit) protection pro-
vides a fault warning indication and shuts down 
the output stage when, for example, an input 
signal is present and a malfunctioning cable or 
driver is short circuiting the output. 
high-impedance
 warning reports an alert when, 
at the same time, output signal is high and no 
current draw is measured. This situation might 
occur when no speakers are connected, or when 
a driver is blown. 
Low inrush current
 ensures that the mains 
breaker  will  not  trip  when  several  power  
amplifiers are turned on simultaneously.
4.2.5  NomadLink / Ethernet control and 
monitoring network
The NomadLink network allows easy setup, monito-
ring, and control of FP+ Series power amplifiers and 
other Lab.gruppen NomadLink-enabled amplifiers. 
The patented network topology provides automatic 
detection  and  addressing  of  multiple  amplifiers, 
and is controlled from a PC via the optional NLB 
60E NomadLink Bridge & Network Controller using 
standard TCP/IP communication. Phantom powering 
through the network cables enables the software 
to detect devices that are not currently turned on 
or connected to the mains. This ensures very high 
reliability and redundancy levels while allowing con-
nected amplifiers to remain on standby with no power 
consumption.  
Cable connections can be daisy-chained for easier 
system setup. This also reduces total component 
costs, simplifies installation, and makes daily opera-
tion more convenient. There is no need to create 
a star topology using many switches as with, for 
example, an Ethernet system. Individual amplifier 
addresses do not need to be manually entered; you 
will automatically know where an individual amplifier 
resides in the network. 
A daisy chain network loop, in combination with 
the  automatic  addressing  of  devices,  enables  
Lab.gruppen’s proprietary DeviceControl software 
to automatically create a precise picture of all con-
nected devices and their relative position in the chain. 
By quickly creating a clear overview of the entire 
system configuration, DeviceControl provides flexible 
control of very large amplifier systems. Set-up time is 
minimized, and critical information is readily available 
for monitoring performance and solving problems 
during operation. 
Via NomadLink, you can monitor all metering data 
as well as all faults and warning indications simulta-
neously. NomadLink also allows you to remotely 
control power on and power off, as well as engage 
Mute and Solo functions on individual channels.