5.3  Cooling 
The amplifier uses a forced-air cooling system with 
air flow from front to rear, maintaining a low operating 
temperature within defined limits. Front-to-rear air-
flow is preferred as cooler air is present at the front in 
nearly all applications. (This allows higher continuous 
power levels without encountering thermal problems.) 
Never attempt to reverse the airflow. The amplifier 
modules require a pressure chamber between the 
fans and heatsink, and this effect functions only in 
one direction.
Make sure that there is an adequate air supply in front 
of the amplifier, and that the rear of the amplifier has 
sufficient space to allow the exhaust to escape. If 
the amplifier is rack-mounted, do not use covers or 
doors on the front or rear of the rack.
 
Should  a  heat  sink  overheat,  the  temperature 
sensing circuits will mute the overheating channel. 
If  the  power  supply  overheats,  another  sensing 
circuit will mute all output channels until the power  
supply cools to safe operating temperature. An early  
warning before shut down will be indicated on the 
front panel LEDs, and a warning will be sent through 
the NomadLink network.
Always make sure that the dust-filters behind the 
detachable front panel are clean to ensure maximum 
possible airflow. 
If the amplifier malfunctions due to dirty 
dust filters, any required repairs are not 
covered by the warranty.
5.4  Operating voltage 
The label placed to the right of the mains 
cable on the rear of the amplifier indicates the 
AC mains voltage for which the amplifier is wired 
and approved: 115 V or 230 V. Connect the power 
cable only to the AC source type referred to on the 
label. The warranty will not cover damage caused by 
connecting to an incorrect type of AC mains.
Lab.gruppen switch mode amplifiers use primary 
switching.  Because  the  mains  power  is  rectified 
directly in front of the transformer, the amplifier is 
insensitive to mains frequency. It may be connected 
to 50 or 60 Hz sources, and actually will operate on 
line frequencies from DC to 400 Hz. 
If  the  power  plug  mounted  at  the  factory  is  not  
appropriate for your country, it can be removed and 
the proper connector wired in its place as follows:
BLACK or BROWN 
 
LIVE
WHITE or BLUE 
 
NEUTRAL
GREEN or GREEN/YELLOW      EARTH(GROUND)
 
 
If  you  are  not  100%  confident  of  your  
competence to replace the mains plug, engage 
qualified personnel to do the job.
Once  a  suitable  AC  supply  is  connected,  the  
amplifier can be turned on using the front panel 
power switch. The amplifier then goes through a 
soft-start sequence as it self-checks its circuits. The 
fans will blow at high speed before dropping to idle, 
and the “power” LED will illuminate.
Inrush power is controlled and limited during “soft- 
start”, enabling multiple amplifiers to be powered up 
simultaneously.
5.5  Grounding 
There is no ground lift switch or terminal on the 
FP+ Series amplifiers. The signal ground is always 
floating, via a resistor, to chassis and therefore the 
grounding system is automatic. 
In the interests of safety, never disconnect the earth 
(ground) pin on the AC power cord.
Use balanced input connections to avoid hum and 
interference.
INsTALLATION  5