PowerDsine
6
The Power over Ethernet Pioneers
1.2 Power
Cord
In the event that the power cord is replaced, the replacement must meet
local requirements.
local requirements.
• For reliable connection to an AC MAINS SUPPLY, equipment
provides an appliance IEC60320 inlet for connection of a
detachable power supply cord.
detachable power supply cord.
• The power socket outlet must be located near the Midspan
and be easily accessible. The only way to remove power from
the unit is by disconnecting the power cord from the outlet
the unit is by disconnecting the power cord from the outlet
•
This unit operates under SELV (Safety Extra Low Voltage)
conditions according to EN60950/IEC 950. The conditions are
only maintained if the equipment to which it is connected, also
operates under SELV conditions.
conditions according to EN60950/IEC 950. The conditions are
only maintained if the equipment to which it is connected, also
operates under SELV conditions.
U.S.A. and
Canada
Canada
The cord must be UL-approved or CSA certified.
The minimum specification for the flexible cord is:
The minimum specification for the flexible cord is:
No. 18 AWG
Type SV or SJ
Three-conductor.
Type SV or SJ
Three-conductor.
The cord set must have a rated current capacity of at least
10 A.
The attachment plug must be an earth-grounding type with a
NEMA 5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V)
configuration.
configuration.
Denmark
The supply plug must comply with section 107-2-D1,
standard DK2-1a or DK2-5a.
Switzerland
The supply plug must comply with SEV/ASE 1011.
France and
Peru
Peru
This unit cannot be powered from IT supplies. If your
supplies are of the IT type, this unit must be powered by 230
V (2P+T), via an isolation transformer with a 1:1 ratio and
with the secondary connection point labeled Neutral,
connected directly to ground
V (2P+T), via an isolation transformer with a 1:1 ratio and
with the secondary connection point labeled Neutral,
connected directly to ground
U.K
The Power over Ethernet Midspan is covered by General
Approval, NS/G/12345/J/100003, for indirect connection to a
public telecommunications system
public telecommunications system