Avaya 3910 Guia Do Utilizador
Electrical
■
10 Watts (35 BTUs/hour) per 400 module, normal and maximum power consumption
Specifications
■
65 Watts (225 BTUs/hour) per 206 module during normal operation
■
100 Watts (350 BTUs/hour) per 206 module during maximum power consumption
■
4 Amps maximum current at full system capacity (processor module and four 206 modules)
On a PARTNER Plus 220V System: 2.2 Amps maximum current
■
4-day memory backup (96 hours)
Processor Module
68000 microprocessor, 64K RAM, 256K ROM
■
Specifications
Extension Jack
Extension Jack
Ringing voltage: +5VDC, -140 VDC peak to peak; trapezoidal wave shaping
■
Specifications
On a PARTNER Plus 220V System: +5VDC, -150 VDC peak to peak
■
35- to 38-Volt talk battery
■
Ringing frequency: 20 Hz
PAGE Jack
■
Draws current on inner wire pair
Specifications
■
Provides contact closure on outer wire pair
■
600 Ohm impedance
SMDR Output
■
1200 baud
Format
■
No parity
■
8 data bits
■
2 stop bits
Environmental
■
Mount on a wall at least 2 feet (0.6 meters) from the floor (wall mounting required)
Requirements—
■
Locate within 5 feet (1.5 meters) of the network interface jacks and an electrical outlet not
Control Unit
controlled by a switch, using supplied 7-foot (2.1-meter) cords
■
Operating temperature 32° to + 104°F (0° to +40°C), not in direct sunlight
■
Humidity 15%–90%, noncondensing
■
For proper ventilation and easy replacement of modules, provide at least 6" (15.2cm) clearance
at the top and sides and 2 feet (0.6 meters) at the front and bottom of the control unit.
at the top and sides and 2 feet (0.6 meters) at the front and bottom of the control unit.
■
Locate in an area free of excess moisture, corrosive gases, dust, and chemicals
Electrical
■
90–130 VAC, 50–60 Hz, 3-prong outlet separate ground, separately fused at 15 Amps
Requirements
On a PARTNER Plus 220V System: 180–264 VAC, fused at 10 Amps
■
Outlet must not be controlled by an on/off switch
■
Grounding to comply with Underwriters Laboratories (UL) 1459:
A. An insulated grounding conductor that is not smaller in size and equivalent in insulation
material and thickness to the grounded and ungrounded branch circuit supply conductors,
except that it is green with or without one or more yellow stripes, is to be installed as part of the
circuit that supplies the product or system.
except that it is green with or without one or more yellow stripes, is to be installed as part of the
circuit that supplies the product or system.
B. The grounding conductor mentioned in item A is to be connected to ground at the service
equipment.
C. The attachment-plug receptacles in the vicinity of the product or system are all to be of a
grounding type, and the grounding conductors serving these receptacles are to be connected
to earth ground at the service equipment.
to earth ground at the service equipment.
Requirements for
Installation of a telephone or other standard (tip/ring) device in another building requires the
Out-of-Building
following In-Range Out-of-Building (IROB) protectors to protect the control unit and device from
Extensions
electrical surges:
■
System phone: two AT&T IROB protectors
■
Standard device: one AT&T IROB protector plus one carbon block protector
A-2
Specifications