Eaton IPC3400-AB-NET Manual Do Utilizador
© 2008 Eaton Corporation. All Rights Reserved. All specifications are subject to change without notice.
www.pulizzi.com • pulizzisales@eaton.com • 800-870-2248 • Fax: 605-334-4999
2
TABLE TOP
• Height 3.43” x Depth 7.5” x Width 5.63”
• Approximate shipping weight is 6 lbs.
• Approximate shipping weight is 6 lbs.
OUTLETS
• IPC3400-A1 has 4 NEMA outlets
• IPC3400-AB has 4 IEC outlets
• IPC3400-AB has 4 IEC outlets
(6) INDICATOR LIGHTS
• (1) Main power
• (1) Data light
• (4) Power on to outlets 1-4
• (1) Data light
• (4) Power on to outlets 1-4
COMMUNICATIONS
• RS232, Serial: 9600 baud only
• Optional ethernet control via RJ45
• Optional ethernet control via RJ45
connector (add -NET to part number)
• Data terminal emulation software is required
to communicate with the IPC internal
command codes such a Telnet or
command codes such a Telnet or
Hyperterminal
MODEM ACCESS
• External Modem must be put in auto-answer
mode prior to making contact with the IPC
EMI/RFI FILTERING
• Common Mode - Line to Ground
• Differential Mode - Line to Line
• Differential Mode - Line to Line
SPIKE/SURGE SUPPRESSION
• L-N, L-G, N-G
POWER INPUT
• IEC C14 power inlet
• Power cable included:
• Power cable included:
-AB version has 8’ C13 to C14
-A1 version has 9’ C13 to 5-15P
-A1 version has 9’ C13 to 5-15P
OUTLET STATUS
• Query the IPC for Outlet and Watchdog
status, i.e. outlets are “on” or “off”
MULTIPLE TIME DELAY
TM
(MTD
TM
)
• Turn outlets “on” or “off” at one time
• Sequence power up and power down to
• Sequence power up and power down to
outlets 1 - 4 with a four second time delay
(factory set)
(factory set)
• Set power “on” sequence to any combination
of outlets
• Set the MTD
TM
timing from 1 second to
999 seconds, i.e. 009 = 9 seconds
PASSWORD PROTECTION
• For added security, a password feature
is included which allows the user to assign
a three alphanumeric character password
a three alphanumeric character password
ADDRESSING
• The IPC comes with a default address
but you can also create your own with
any four alphanumeric characters
any four alphanumeric characters
WATCH-DOG/AUTO-REBOOT
• The IPC will monitor the control connection
and automatically reboot itself if the
connection locks up. The auto-reboot is
activated by the time-out period running
down to zero. When this occurs the IPC will
shut down all outlets for four seconds and
restart in the default or user defined sequence
connection locks up. The auto-reboot is
activated by the time-out period running
down to zero. When this occurs the IPC will
shut down all outlets for four seconds and
restart in the default or user defined sequence
• Set the Time Out Period to any number 0-9
where each digit represents 30 seconds,
i.e. 3 = 120 seconds (user defined)
i.e. 3 = 120 seconds (user defined)
COMMANDS AVAILABLE
• All outlets on/off
• Individual outlet on/off
• Set up and Sequence on/off all outlets
• Create password and unit address
• Name outlets with 8 character name
• Set up, enable or disable Watchdog
• Display outlet and Watchdog Timer status
• Individual outlet on/off
• Set up and Sequence on/off all outlets
• Create password and unit address
• Name outlets with 8 character name
• Set up, enable or disable Watchdog
• Display outlet and Watchdog Timer status
IPC3400-A1-NET Rear
SPECIFICATIONS
IPC3400-A1
IPC3400-A1-NET
IPC3400-AB
IPC3400-AB-NET
Approvals
NA
NA
NA
NA
Voltage Input/Output (50/60Hz)
120V~
120V~
100-240V~
100-240V~
Current Input
15A
15A
15A
15A
Current Output
12A
12A
12A
12A
Full Load VA
1440VA
1440VA
1440VA/2880VA
1440VA/2880VA
NEMA Outlets (rear panel)
5-15R
5-15R
IEC 60320 Type C13
IEC 60320 Type C13
EMI/RFI Filter
15A
15A
15A
15A
Surge Suppression
270V
270V
270V
270V
Power Cord/Length (rear panel)
14/3, 9’
14/3, 9’
14/3, 8’
14/3, 8’
Power Input Plug
5-15P
5-15P
IEC 60320 Type C14
IEC 60320 Type C14
Serial Control (RS232)
YES
YES
YES
YES
Ethernet Control
NO
YES
NO
YES