D-Link DAS-3224 Manual Do Utilizador

Página de 202
D-Link DAS-3248/3224 IP DSLAM 
 
 
                                                                 
 
72 
 
2. 
To creat a new alarm profile, click the DSL Name drop-down list 
and then select the blank. 
3. 
After that, the fields become enable. Input the values in those fields 
and then name the new alarm profile. 
4. Click 
on 
  to submit your setting or click on 
 to 
deliete a alarm profile. 
Table 4-8 Alarm Profile Field Definitions 
Field 
Definition 
Loss of frame within 15 
minutes 
The threshold of the number of “Loss of Frame 
Seconds” within 15 minutes performance data 
collection period. 
Loss of signal within 15 
minutes 
The threshold of the number of “Loss of Signal 
Seconds” within 15 minutes performance data 
collection period. 
Loss of link within 15 
minutes 
The threshold of the number of “Loss of Link 
Seconds” within 15 minutes performance data 
collection period. (But only ATU-C side) 
Loss of power within 15 
minutes  
The threshold of the number of “Loss of Power 
Seconds” within 15 minutes performance data 
collection period. 
Errored seconds 
The threshold of the number of “Errored Seconds” 
within 15 minutes performance data collection period.
4.7.2 Port Configuration 
Allow users to proceed port configuration. The procedures are as follows: