INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.
Tools Needed
 
Phillips screwdriver
 
Measuring tape
 
Level
 
Hand or electric drill (for 
wall cabinet installations)
 
1" (25 mm) drill bit (for wall 
cabinet installations)
Parts Needed
 
UL-listed or CSA-approved conduit connector
 
UL-listed wire connectors
Parts Supplied
 
Four # 8-14 x 1" screws
 
Right and left side trim
 
Bottom vent (supplied on some models)
 
Bottom vent trim
 
Two # 8-18 x ³⁄
8
" screws – bottom vent
Check local codes. Check existing electrical supply.  
See “Electrical Requirements.”
It is recommended that all electrical connections be made  
by a licensed, qualified electrical installer.
Product Dimensions – Single Oven
Location Requirements
IMPORTANT: Observe all governing codes and ordinances. 
 
Cabinet opening dimensions that are shown must be used. 
Given dimensions provide minimum clearance with oven.
 
Recessed installation area must provide complete 
enclosure around the recessed portion of the oven.
 
Grounded electrical supply is required. See “Electrical 
Requirements” section.
 
Electrical supply junction box should be located 3"  
(7.6 cm) maximum below the support surface when the 
oven is installed in a wall cabinet. A 1" (2.5 cm) minimum 
diameter hole should have been drilled in right rear or the 
left rear corner of the support surface to pass the appliance 
cable through to the junction box. 
  
NOTE: For undercounter installation, it is recommended 
that the junction box be located in the adjacent right or 
left cabinet. If you are installing the junction box on rear 
wall behind oven, the junction box must be recessed and 
located in the upper or lower right or left corner of the 
cabinet; otherwise, the oven will not fit into the cabinet 
opening.
 
Oven support surface must be solid, level, and flush with 
bottom of cabinet cutout. Floor must be able to support 
a single oven weight of 140 lbs (63.5 kg) or a double oven 
weight of 245 lbs (111.1 kg).
Undercounter Installation (with cooktop installed above):
Ovens approved for this type of installation have an approval 
label located on the top of the oven. Refer to undercounter 
installation instructions for cutout dimensions and approved 
oven cooktop combinations (separate sheet).
Cabinet Dimensions – Single Oven
Single Oven Undercounter (without cooktop installed above)
A. 22³⁄
8
" (56.8 cm) max. recessed width
B. 29" (73.7 cm) max. overall height
C. 23³⁄
4
" (60.3 cm) overall width
D. 23" (58.4 cm) max. recessed depth
E. 27¹⁄
2
" (69.9 cm) recessed height
A. 24" (61 cm) min. cabinet width
B.   1¹⁄
2
" (3.8 cm) min. top of cutout  
to underside of countertop
C.   5¹⁄
4
" (13.3 cm) bottom of cutout to floor
D. 22
5
8
" (57.5 cm) cutout width
E. 27³⁄
4
" (70.5 cm) min. cutout height
A
B
C
D
E
A
B
C
D