Netgear M4300-24X24F (XSM4348S) - Stackable Managed Switch with 48x10G including 24x10GBASE-T and 24xSFP+ Layer 3 Guia Do Programa
Switch Software Log Messages
1101
M4200 and M4300 Series ProSAFE Managed Switches
Technologies
Table 70. Error Messages
Component
Message
Cause
OS
Invalid USP unit = x, slot = x, port = x
A port was not able to be translated correctly
during the receive.
OS
In hapiBroadSystemMacAddress call to
'bcm_l2_addr_add' - FAILED : x
'bcm_l2_addr_add' - FAILED : x
Failed to add an L2 address to the MAC table.
This should only happen when a hash collision
occurs or the table is full.
This should only happen when a hash collision
occurs or the table is full.
OS
Failed installing mirror action - rest of the policy
applied successfully
applied successfully
A previously configured probe port is not being
used in the policy. The release notes state that
only a single probe port can be configured.
only a single probe port can be configured.
OS
Policy x does not contain rule x
The rule was not added to the policy due to a
discrepancy in the rule count for this specific
policy. Additionally, the message can be
displayed when an old rule is being modified, but
the old rule is not in the policy.
discrepancy in the rule count for this specific
policy. Additionally, the message can be
displayed when an old rule is being modified, but
the old rule is not in the policy.
OS
ERROR: policy x, tmpPolicy x, size x, data x x x x
x x x x
x x x x
An issue installing the policy due to a possible
duplicate hash.
OS
ACL x not found in internal table
Attempting to delete a non-existent ACL.
OS
ACL internal table overflow
Attempting to add an ACL to a full table.
OS
In hapiBroadQosCosQueueConfig, Failed to
configure minimum bandwidth. Available
bandwidth x
configure minimum bandwidth. Available
bandwidth x
Attempting to configure the bandwidth beyond it’s
capabilities.
OS
USL: failed to put sync response on queue
A response to a sync request was not enqueued.
This could indicate that a previous sync request
was received after it was timed out.
was received after it was timed out.
OS
USL: failed to sync ipmc table on unit = x
Either the transport failed or the message was
dropped.
dropped.
OS
usl_task_ipmc_msg_send(): failed to send with x Either the transport failed or the message was
dropped.
OS
USL: No available entries in the STG table
The Spanning Tree Group table is full in USL.
OS
USL: failed to sync stg table on unit = x
Could not synchronize unit x due to a transport
failure or API issue on remote unit. A
synchronization retry will be issued.
failure or API issue on remote unit. A
synchronization retry will be issued.
OS
USL: A Trunk doesn't exist in USL
Attempting to modify a Trunk that doesn’t exist.
OS
USL: A Trunk being created by bcmx already
existed in USL
existed in USL
Possible synchronization issue between the
application, hardware, and sync layer.
application, hardware, and sync layer.
OS
USL: A Trunk being destroyed doesn't exist in
USL
USL
Possible synchronization issue between the
application, hardware, and sync layer.
application, hardware, and sync layer.