Utility Commands 
313
 M4200 and M4300 Series ProSAFE Managed Switches
Power Management Commands
power redundancy
This command enables the N+1 power redundancy feature on a switch with a dual PSU 
configuration. If this feature is enabled, only one PSU provides 56V PoE power to the unit. If 
the PSU fails, the redundant PSU seamlessly takes over the supply of 56V PoE power to the 
unit. If this command is disabled, N+1 is also disabled and both PSUs provide 56V PoE 
power to the unit at the same time. In this situation, the PoE budget for the unit increases.
The unit-number argument specifies the PSU in the switch.
Note:
If the total available power minus the total consumed power is less 
than what one PSU can supply, the switch does not enable the N+1 
feature. Instead, it generates the following error message on the 
console and in the logging buffer:
Not enough power to enable N+1 feature. Total 
available power: <X>. Total consumption power: <Y> 
no power redundancy
This command disables the N+1 power redundancy feature. 
show power redundancy
This command displays the power redundancy status.
Command example: 
(NETGEAR Switch)# show power redundancy 
N+1 configuration: ............................ Disable
N+1 Active: ................................... No
Number of PSU: ................................ 1
Effective Number of PSU: ...................... 1
Default
Disabled
Format
power redundancy [unit-number]
Mode
Global Config
Format
no power redundancy
Mode
Global Config
Format
show power redundancy
Mode
Privileged EXEC