Netgear M4300-24X24F (XSM4348S) - Stackable Managed Switch with 48x10G including 24x10GBASE-T and 24xSFP+ Layer 3 Guia Do Programa
Utility Commands
312
M4200 and M4300 Series ProSAFE Managed Switches
telnetd
Use this command in Support mode to start or stop the Telnet daemon on the switch.
Cable Test Command
The cable test feature enables you to determine the cable connection status on a selected
port.
port.
Note:
The cable test feature is supported only for copper cable. It is not
supported for optical fiber cable.
supported for optical fiber cable.
If the port has an active link while the cable test is run, the link can go down for the duration of
the test.
the test.
cablestatus
This command returns the status of the specified port.
Format
telnetd {start | stop}
Mode
Support
Format
cablestatus unit/slot/port
Mode
Privileged EXEC
Field
Description
Cable Status
One of the following statuses is returned:
•
Normal
. The cable is working correctly.
•
Open
. The cable is disconnected or there is a faulty connector.
•
Short
. There is an electrical short in the cable.
•
Cable Test Failed
. The cable status could not be determined. The cable may in fact be
working.
Cable Length
If this feature is supported by the PHY for the current link speed, the cable length is displayed as a
range between the shortest estimated length and the longest estimated length. Note that if the link is
down and a cable is attached to a 10/100 Ethernet adapter, then the cable status may display as
Open or Short because some Ethernet adapters leave unused wire pairs unterminated or grounded.
Unknown is displayed if the cable length could not be determined.
range between the shortest estimated length and the longest estimated length. Note that if the link is
down and a cable is attached to a 10/100 Ethernet adapter, then the cable status may display as
Open or Short because some Ethernet adapters leave unused wire pairs unterminated or grounded.
Unknown is displayed if the cable length could not be determined.