Netgear M4300-24X24F (XSM4348S) - Stackable Managed Switch with 48x10G including 24x10GBASE-T and 24xSFP+ Layer 3 Guia Do Administrador

Página de 688
iSCSI 
675
 Managed Switches
Enable iSCSI Awareness with VLAN Priority Tag
The example is shown as CLI commands and as web interface procedure.
CLI: Enable iSCSI Awareness with VLAN Priority Tag
Use the following commands to enable iSCSI awareness, select VPT, and set VLAN number 
and aging time.
Web Interface: Enable iSCSI Awareness with VLAN Priority Tag
1. 
Enable iSCSI awareness, select VPT, and set VLAN number and aging time.
a. Select Switching > iSCSI > Basic.
A screen similar to the following displays.
b.  Enter the following information:
Next to iSCSI Status, select the Enable radio button.
Next to QoS Profile, select the VLAN Priority Tag radio button.
From the VLAN Priority Tag menu, select 5 (the default value).
Next to Remark, select the Enable radio button (the default value).
In the iSCSI Aging Time field, enter 10 (the default value).
c.  Click Apply to save the settings.
(Netgear Switch) #config
(Netgear Switch) (Config) #iscsi enable
(Netgear Switch) (Config) #iscsi cos vpt 5
(Netgear Switch) (Config) #iscsi aging time 10
(Netgear Switch) (Config) #exit