This specifies the GARP multicast registration protocol administrative mode for the port. If
you select Disable, the protocol is not active, and the join time, leave time, and leave all
time have no effect. The factory default is Disable.
you select Disable, the protocol is not active, and the join time, leave time, and leave all
time have no effect. The factory default is Disable.
9.
In the Join Time (centiseconds) field, specify the time between the transmission of GARP
PDUs registering (or re-registering) membership for a VLAN or multicast group in
centiseconds.
Enter a number between 10 and 100 (0.1 to 1.0 seconds). The factory default is 20
centiseconds (0.2 seconds). An instance of this timer exists for each GARP participant for
each port.
centiseconds (0.2 seconds). An instance of this timer exists for each GARP participant for
each port.
10.
In the Leave Time (centiseconds) field, specify the time to wait after receiving an
unregister request for a VLAN or multicast group before deleting the associated entry, in
centiseconds.
This allows time for another station to assert registration for the same attribute to
maintain uninterrupted service. Enter a number between 20 and 600 (0.2 to 6.0 seconds).
The factory default is 60 centiseconds (0.6 seconds). An instance of this timer exists for
each GARP participant for each port.
maintain uninterrupted service. Enter a number between 20 and 600 (0.2 to 6.0 seconds).
The factory default is 60 centiseconds (0.6 seconds). An instance of this timer exists for
each GARP participant for each port.
11.
Use Leave All Time (centiseconds) to control how frequently LeaveAll PDUs are
generated.
A LeaveAll PDU indicates that all registrations will be deregistered soon. To maintain
registration, participants must rejoin. The leave all period timer is set to a random value in
the range of LeaveAllTime to 1.5*LeaveAllTime. The timer is specified in centiseconds.
Enter a number between 200 and 6000 (2 to 60 seconds). The factory default is 1000
centiseconds (10 seconds). An instance of this timer exists for each GARP participant for
each port.
the range of LeaveAllTime to 1.5*LeaveAllTime. The timer is specified in centiseconds.
Enter a number between 200 and 6000 (2 to 60 seconds). The factory default is 1000
centiseconds (10 seconds). An instance of this timer exists for each GARP participant for
each port.
12.
Click the Apply button.
The updated configuration is sent to the switch. Configuration changes take effect
immediately.
immediately.
Auto-VoIP
You can configure protocol-based port settings and OUI settings.
Configure Protocol-Based Port Settings
To configure protocol-based port settings:
1.
Launch a web browser.
2.
Enter http://<ipaddress> in the web browser address field.
The login window opens.
3.
Enter the user name and password.
The default admin user name is admin and the default admin password is blank, that is,
do not enter a password.
do not enter a password.