Monitor the System 
648
M4200 and M4300 Series ProSAFE Managed Switches Web Management User Manual 
Configure an sFlow Receiver
Use the sFlow Receiver Configuration page to configure the sFlow Receiver.
To configure an sFlow receiver:
1. 
Launch a web browser.
2. 
Enter http://<ipaddress> in the web browser address field.
The login window opens.
3. 
Enter the user name and password. 
The default admin user name is admin and the default admin password is blank, that is, 
do not enter a password.
4. 
Click the Login button. 
The System Information page displays.
5. 
Select Monitoring
> sFlow > Advanced > sFlow Receiver Configuration.
6. 
Next to the Receiver Index columns, select the check box for the receiver for which data 
must be displayed or configured. 
The allowed range to 1 to 8.
7. 
In the Receiver Owner field, specify the receiver owner. 
This is the entity making use of this sFlowRcvrTable entry. The empty string indicates that 
the entry is currently unclaimed and the receiver configuration is reset to the default 
values. An entity wishing to claim an sFlowRcvrTable entry must ensure that the entry is 
unclaimed before trying to claim it. The entry is claimed by setting the owner string. The 
entry must be claimed before any changes can be made to other sampler objects. 
8. 
In the Receiver Timeout field, specify the time (in seconds) remaining before the sampler is 
released and stops sampling. 
A management entity wanting to maintain control of the sampler is responsible for setting 
a new value before the old one expires. The valid range is 0 to 2147483647. A value of 
zero essentially means the receiver is not configured and sets the selected receiver 
configuration to its default values. When configuring the sFlow receiver settings, you must 
select the Timeout Mode option before you can configure a Timeout Value.
9. 
From the No Timeout menu, select True or False to set the no time-out sampling for the 
receiver.