Netgear XS728T – ProSAFE® 10 Gigabit Smart Managed Switch Guia Do Administrador

Página de 204
Monitoring 
157
 XS728T ProSAFE 28-Port 10-Gigabit L2+ Smart Switch
Untested. The test has not been performed.
Cable Length. The estimated length of the cable in meters. The length is displayed 
as a range between the shortest estimated length and the longest estimated length. 
This is of rough accuracy (0–50m, 50–80m, 80–110m). Not Supported is displayed if 
the cable length was not determined. The cable length is displayed only if the cable 
status is Normal.
Failure Location. The estimated distance in meters from the end of the cable to the 
failure location. The failure location is displayed only if the cable status is Open 
Cable, Short Cable, or No Cable.
Logs
The switch might generate messages in response to faults, or errors occurring on the 
platform as well as changes in configuration or other occurrences. These messages are 
stored locally and can be forwarded to one or more centralized points of collection for 
monitoring purposes or long-term archival storage. Local and remote configuration of the 
logging capability includes filtering of messages logged or forwarded based on severity and 
generating component.
The Logs tab contains menus that provide access to the following features
Buffered Logs
The buffered log stores messages in RAM memory based on the settings for message 
component and severity. Use the Buffered Logs screen to set the administrative status and 
behavior of logs in the system buffer. These log messages are cleared when the switch 
reboots.
To configure the Buffered Logs settings:
1. 
Select Monitoring > Logs > Buffered Logs.
2. 
In the Admin Status field select Enable to enable system logging or Disable to disable it. 
The factory default setting is Enable.
3. 
In the Behavior field, select the Wrap behavior of the log when it is full.
In this behavior, when the buffer is full, the oldest log messages are deleted as the 
system logs new messages.
4. 
If you change the buffered logs settings, click Apply to apply the changes to the system and 