Netgear FS516 - 16 Port 10/100 Mbps Fast Ethernet Switch Guia Da Instalação

Página de 42
Installation Guide for the Model FS516 Fast Ethernet Switch
C-2
Cabling Guidelines
 
Cable Lengths
Category 5 distributed cable that meets ANSI/EIA/TIA-568-A building wiring standards can be 
a maximum of 328 feet (100 meters) in length, divided as follows:
20 feet (6 meters) between the hub and the patch panel (if used)
295 feet (90 meters) from the wiring closet to the wall outlet
10 feet (3 meters) from the wall outlet to the desktop device
The patch panel and other connecting hardware must meet the requirements for 100 Mbps 
operation (Category 5). Only 0.5 inch (1.5 cm) of untwist in the wire pair is allowed at any 
termination point.
Cable Specifications
 lists the electrical requirements of Category 5 cable.
Table C-1.
Electrical Requirements of Category 5 Cable
Specification
Category 5 Cable
Number of pairs
Four
Impedance
100 
Ω
 
±
 15%
Mutual capacitance at 1 KHz
 5.6 nF per 100 m
Maximum attenuation (dB per 100 m, at 20
°
 C) at 4 MHz: 8.2
at 31 MHz: 11.7
at 100 MHz: 22.0
NEXT loss (dB minimum)
at 16 MHz: 44
at 31 MHz: 39
at 100 MHz: 32