KitchenAid 36" Designer Commercial-Style Hood Utilização E Cuidado

Página de 28
4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. 
Read and follow the safety instructions provided with any tools 
listed here.
Tools needed
Level
Drill
1¹⁄₄" (3.0 cm) drill bit
Pilot hole drill bits (determined by chimney support 
attachment method)
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Jigsaw or keyhole saw
Flat-blade screwdriver
Phillips screwdriver
Vent clamps
Metal snips
Parts needed
1 UL listed or CSA approved, 
¹⁄₂" (12.5 mm) strain relief
2 UL listed wire connectors
Home power supply cable
4 Concrete anchors for 
¹⁄₄" x 4" hex head lag bolts
(for concrete installation)
1 Wall or roof cap
Metal vent system
Parts supplied
Remove parts from packages. Check that all parts were included.
Hood canopy assembly with ventilator and light bulbs 
installed
3 Filters (4 filters for 48" [121.9 cm] hood)
Chimney assembly
Ceiling mounting template
Upper chimney cover
Lower chimney cover
Parts bag containing: 
Damper (2 dampers for 48" [121.9 cm] hood)
4 Hex washer head bolts (for attaching canopy to 
chimney support)
4 Hex washer head wood bolts (for attaching chimney 
support to ceiling)
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the 
installer's responsibility to comply with installation clearances 
specified on the model/serial rating plate. The model/serial rating 
plate is located inside the range hood on the rear wall of the 
range hood.
Island hood location should be away from strong draft areas, 
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given 
dimensions provide minimum clearance.
It is recommended that the hood be fastened into solid wood.
The island hood is factory set for venting through the roof or 
through the wall. 
All openings in ceiling and where island hood will be installed 
must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the 
Manufactured Home Construction Safety Standards, Title 24 
CFR, Part 328 (formerly the Federal Standard for Mobile Home 
Construction and Safety, Title 24, HUD, Part 280) or when such 
standard is not applicable, the standard for Manufactured Home 
Installation 1982 (Manufactured Home Sites, Communities and 
Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local 
codes.
Product Dimensions
Vented Installations
11
¹⁄₃
" (28.6 cm)
23
⁹⁄₁₆
" (59.9 cm)
36" (91.4 cm),
42" (106.7 cm) or
48" (121.9 cm)
27
⁹⁄₁₆
" (70.0 cm)
31
¹⁄₂
" (80.0 cm)
          min.  
46³⁄₄
" (118.8 cm)
          max.  
23
⁵⁄₈
" (60.0 cm)