Venting Requirements
Vent system must terminate to the outdoors.
Do not terminate the vent system in an attic or other enclosed 
area.
Do not use 4" (10.2 cm) laundry-type wall caps.
Use metal vent only. Rigid metal vent is recommended. 
Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should be 
kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight 
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper. If the roof or wall cap 
has a damper, do not use the damper supplied with the range 
hood.
Use caulking to seal exterior wall or roof opening around the 
cap.
The size of the vent should be uniform.
Cold weather installations
An additional back draft damper should be installed to minimize 
backward cold air flow and a thermal break should be installed to 
minimize conduction of outside temperatures as part of the vent 
system. The damper should be on the cold air side of the thermal 
break.
The break should be as close as possible to where the vent 
system enters the heated portion of the house.
Makeup air
Local building codes may require the use of makeup air systems 
when using ventilation systems greater than specified CFM of air 
movement. The specified CFM varies from locale to locale. 
Consult your HVAC professional for specific requirements in your 
area.
Venting Methods
A 6" (15.2 cm) round vent system is needed for installation (not 
included). The range hood exhaust opening is 6" (15.2 cm) round. 
Two 6" (15.2 cm) round vent systems are needed for installation 
on 48" (121.9 cm) models.
NOTE: Flexible vent is not recommended. Flexible vent creates 
back pressure and air turbulence that greatly reduce 
performance.
Vent system can terminate either through the roof or wall. To vent 
through the wall, a 90º elbow is needed.
*The 48" (121.9 cm) range hood uses two 6" (15.2 cm) round 
vents or transitions to 10" (25.4 cm) round vent using Part 
Number 4396915.
Calculating Vent System Length
To calculate the length of the system you need, add the 
equivalent feet (meters) for each vent piece used in the system.  
The maximum equivalent vent lengths are:
6" (15.2 cm) round vent - 35 ft (10.7 m)
7" (17.8 cm) round vent - 40 ft (12.2 m)
8" (20.3 cm) round vent - 50 ft (15.2 m)
9" (22.9 cm) and 10" (25.4 cm) round vents - 60 ft (18.3 m)
Example vent system
The following example falls within the maximum recommended 
vent length.
Roof Venting
Wall Venting
A. Roof cap
B. 6" (15.2 cm) 
round vent*
A. Wall cap
B. 6" (15.2 cm) 
round vent*
Vent Piece
Equivalent Length
45° elbow
2.5 ft
(0.8 m) 
90° elbow
5.0 ft
(1.5 m)
1 - 90° elbow
= 5.0 ft (1.5 m)
1 - wall cap
= 0.0 ft (0.0 m)
8 ft (2.4 m) straight
= 8.0 ft (2.4 m)
Length of system
= 13.0 ft (3.9 m)
A
A
B*
B*
90  elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap