Cisco Cisco C880 M4 Server

Página de 83
CHAPTER 3 Replacement of HDD/SSD 
3.1 Hot replacement of HDD/SSD with Hardware RAID configuration 
31 
 
C122-E175-01EN 
 
 Replacement of HDD/SSD 
CHAPTER 3
This chapter describes how to replace Hard Disk Drives (HDD) or Solid State Drives (SSD). 
In Cisco C880 M4 server (E7-8800 v3 CPU), it is required to use HII Configuration Utility for replacing a HDD 
or SSD. 
In Cisco C880 M4 server (E7-8800 v2 CPU), it is required to use WebBIOS for replacing a HDD or SSD. 
3.1 
Hot replacement of HDD/SSD with Hardware RAID 
configuration 
This section describes how to replace Hard Disk Drives (HDD) or Solid State Drives (SSD) with Hardware 
RAID configuration. 
3.1.1  Hot replacement of failed HDD/SSD with RAID0 configuration 
This section describes the workflow of hot replacement of HDD or SSD with RAID0 configuration when one 
HDD or SSD fails. 
Remarks 
Hot replacement of HDD or SSD can be performed only when HDDs or SSDs are mirror configuration by 
using software. 
Step1 and Step2 are performed by field engineers in charge of your system. 
1.  Replace HDD or SSD with the Alarm LED on by using MMB Maintenance Wizard. 
2.  Create a logical drive with RAID0 configuration by using MMB Maintenance Wizard. 
3.  Confirm whether [Status] of replaced HDD or SSD has been already 
‘Operational’ by MMB Web-UI. How 
to confirm the status differs depending on whether the HDD or SSD is included or in a DU. 
3.1.2  Hot replacement of failed HDD/SSD with RAID 1, RAID 1E, RAID 5, 
RAID 6, or RAID 10 configuration 
This section describes the workflow of hot replacement of HDD or SSD with RAID 1, RAID 1E, RAID 5, RAID 
6, or RAID 10 configuration when one HDD or SSD fails. 
Remarks 
Step1 is performed by field engineers in charge of your system. 
Copy back may run after rebuild has been completed. 
1.  Replace the HDD or SSD with the Alarm LED on by using MMB Maintenance Wizard. 
Note 
When set a spare disk, set the HDD or SSD to the spare disk by using Maintenance Wizard if the status 
of the replaced HDD or SSD is 
‘Available’. 
2.  Confirm whether a rebuild of the HDD or SSD has been already completed by using the below steps 
depending on whether a spare disk is set or not. 
-  If not set a spare disk 
A rebuild is automatically performed to replaced HDD or SSD. Then, the Alarm LED of the HDD or 
SSD starts blinking. 
Confirm whether a rebuild of replaced HDD or SSD has been already completed by MMB Web-UI. 
How to confirm the status differs depending on whether the HDD or SSD is included in a DU. 
-  If set a spare disk: 
A rebuild has been already automatically performed to the HDD or SSD set as a spare disk. The 
replaced HDD or SSD automatically becomes a spare disk. The Alarm LED of the HDD or SSD goes 
out. 
Confirm whether [Status] of replaced HDD or SSD has been already 
‘Hot spare’ by MMB Web-UI. How 
to confirm the status differs depending on whether the HDD or SSD is included in a DU.