Cisco Cisco C880 M4 Server

Página de 83
CHAPTER 3 Replacement of HDD/SSD 
3.2 Preventive replacement of HDD/SSD with Hardware RAID configuration 
32 
 
C122-E175-01EN 
3.2 
Preventive replacement of HDD/SSD with Hardware RAID 
configuration 
This section describes how to perform the preventive replacement of Hard Disk Drives (HDD) or Solid State 
Drives (SSD) with Hardware RAID configuration. 
3.2.1  Preventive replacement of failed HDD/SSD with RAID0 
configuration 
This section describes the workflow of preventive replacement of HDD or SSD with RAID0 configuration. 
For mirror configuration 
Hot preventive replacement can be performed if HDDs or SSDs are mirror configuration by software. 
Remarks 
Step1 and Step2 are performed by field engineers in charge of your system. 
If HDD or SSD other than target HDD or SSD for preventive replacement fails in step3, field engineers in 
charge of your system replace the failed HDD or SSD. 
1.  Replace HDD or SSD with the Alarm LED on by using MMB Maintenance Wizard. 
2.  Create a logical drive with RAID0 configuration by using MMB Maintenance Wizard. 
3.  Confirm whether [Status] of replaced HDD or SSD has been already 
‘Operational’ by MMB Web-UI. How 
to confirm the status differs depending on whether the HDD or SSD is included in a DU. 
For non-mirror configuration (replacement with the system power off) 
If HDDs or SSDs are not mirror configuration, preventive replacement of a HDD or SSD has to be performed 
with the system power off 
Remarks 
If HDD or SSD other than target HDD or SSD for preventive replacement fails in step3, field engineers in 
charge of your system replace the failed HDD or SSD. 
Step7 is performed by the field engineer in charge of your system. 
1.  Back up data in all HDDs or SSDs connected to the RAID controller card to which the target HDD or SSD 
for preventive replacement is connected. 
2.  Confirm the HDD or SSD which S.M.A.R.T. has predicted to fail by MMB Web-UI checking mounting 
location. How to confirm the status differs depending on whether the HDD or SSD is included in a DU. 
3.  If HDD or SSD other than target HDD or SSD for preventive replacement fails, replace the failed HDD or 
SSD prior to perform preventive replacement 
4.  Restart the system. 
In C880 M4 server (E7-8800 v3 CPU), start HII Configuration Utility from Boot Manager front page. 
In C880 M4 server (E7-8800 v2 CPU), Start WebBIOS from Boot Manager front page. 
5.  In C880 M4 server (E7-8800 v3 CPU), Perform Clear Configuration. 
Selet [Clear Configuration] from [Configuration Utility] in [HII Configuration Utility]. 
Note 
If you perform [Clear Configuration], all data are deleted. 
In C880 M4 server (E7-8800 v2 CPU), Perform Clear Configuration or delete a VD. 
-  For there is only one VD with RAID 0: 
-  Select [Clear Configuration] from [Configuration Wizard] in [WebBIOS] and click [Next]. 
-  If below massage appears, click [Yes]. 
“This is Destructive Operation. 
Original configuration and data will be lost. 
Select Yes, if desired so.
” 
Note 
If you perform [Clear Configuration], all data are deleted. [Configuration Preview] window appears.