Cisco Cisco UCS 6120XP 20-Port Fabric Interconnect Ficha De Dados

Página de 30
 
 
© 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. 
Page 28 of 30 
Table 4. 
Power Specifications for the Cisco UCS 6140XP Fabric Interconnect 
 
Description 
Specification 
AC-input voltage  
90 to 264 VAC 
AC-input frequency  
50 to 60 Hz nominal (Range: 47 to 63 Hz) 
AC-input current 
9.2 Amps @ 90 VAC  
Maximum input VA 
828 VA @ 90 VAC 
Maximum output power per power supply 
750W @ 12 VDC (up to two power supplies) 
Maximum inrush current 
35 A <sub cycle duration 
Maximum heat output 
2561 BTU/hr 
Maximum hold-up time  
12 ms 
Power supply output voltage 
12 VDC 
Efficiency rating 
89% (Climate Savers Gold qualified) 
 
Note:   AC input connector is an IEC 320 C-14 15A/250VAC power inlet. 
For configuration specific power specifications, use the Cisco UCS Power Calculator: 
 
 
Environmental Specifications 
Table 5. 
Environmental Specifications for the Cisco UCS 6100 Series Fabric Interconnects 
 
Environment  
Specification 
Temperature operating  
0°C to 40°C (32°F to 104°F) 
Temperature nonoperating  
-40°C to 70°C (-40°F to 158°F) 
Altitude operating 
0 to 3,000 m (0 to 10,000 ft.) 
Humidity (RH), noncondensing  
5 to 95%, non condensing  
 
 
 
 
 
 
Contents: