Cisco Cisco UCS 6120XP 20-Port Fabric Interconnect Ficha De Dados
© 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 28 of 30
Table 4.
Power Specifications for the Cisco UCS 6140XP Fabric Interconnect
Description
Specification
AC-input voltage
90 to 264 VAC
AC-input frequency
50 to 60 Hz nominal (Range: 47 to 63 Hz)
AC-input current
9.2 Amps @ 90 VAC
Maximum input VA
828 VA @ 90 VAC
Maximum output power per power supply
750W @ 12 VDC (up to two power supplies)
Maximum inrush current
35 A <sub cycle duration
Maximum heat output
2561 BTU/hr
Maximum hold-up time
12 ms
Power supply output voltage
12 VDC
Efficiency rating
89% (Climate Savers Gold qualified)
Note: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.
For configuration specific power specifications, use the Cisco UCS Power Calculator:
Environmental Specifications
Table 5.
Environmental Specifications for the Cisco UCS 6100 Series Fabric Interconnects
Environment
Specification
Temperature operating
0°C to 40°C (32°F to 104°F)
Temperature nonoperating
-40°C to 70°C (-40°F to 158°F)
Altitude operating
0 to 3,000 m (0 to 10,000 ft.)
Humidity (RH), noncondensing
5 to 95%, non condensing