Cisco Headend System Release 2.7 Guia Do Utilizador

Página de 90
 
Chapter 3    tru2way Diagnostic Screens 
 
 
 
68 
78-4011047-01 Rev D 
Field Names  Description 
Possible Values 
OOB 
Network RDC 
PWR 
The output level of the QPSK 
transmitter 
 
Refer to specific hardware 
specifications 
•  value displayed in white
signal level is nominal 
•  value displayed in amber
signal level is marginally too 
high or too low 
• 
value displayed in red
signal level is unacceptably too 
high or too low
 
OOB IP 
The IP address assigned to the 
out-of-band Ethernet adapter 
 
[Network-dependent] 
Example: 10.1.0.1
 
Current 
Tuner in 
Focus 
Type of tuner currently in focus 
 
Unavailable
 
CCI  
(tuner 1, 2) 
Displays the copy control 
information (CCI) for each tuner 
in the host 
CCI 
Possible values: 
 
0x0—Copy Freely 
 
0x1—No More 
 
0x2—Copy Once 
 
0x3—Copy Never 
 
0x4—Copy status undefined
 
Tune Counts 
(tuner 1, 2) 
Displays the number of tuning 
incidents on the host 
 
[Integer > 0], [Integer > 0]