Enterprise service
LRM service
Recording and Statistics service
The LRM service controls the failover logic for this subset. Two failures of the same 
service within five minutes causes failover of the subset. One LRM failure causes 
failover of the subset.
Agent Desktop, Supervisor Desktop, and CAD-BE
The service autorecovery feature enables Agent Desktop, Supervisor Desktop, and 
CAD-BE to automatically recover their connections to the CAD services in the case of a 
service restart or a network outage. 
When Agent Desktop, Supervisor Desktop, or CAD-BE detects that it is unable to 
communicate with a service (generally within one minute of the service failure), the 
application status bar displays “Partial Service” or “No Service” to indicate some or all 
of the services have failed. 
When Agent Desktop, Supervisor Desktop, or CAD-BE detects that the service is again 
available (usually within one minute of service recovery), the status bar displays “In 
Service” to indicate the services have recovered.
To learn more about what is affected by the service failure, double-click the status 
message on the status bar. The application displays a popup box that lists the 
application features and indicates if that feature is available or not due to the service 
outage.
CAD-BE
CAD-BE displays a dialog box when a service goes down or comes back up. If the 
BIPPA service is down, all ACD, call control, task, and workflow capabilities are 
disabled. CAD-BE attempts to reconnect to the service. If it is unable to do so and 
there is a redundant BIPPA service, it automatically attempts to connect to the 
redundant BIPPA service. 
If CAD-BE is unable to connect to the BIPPA service specified by the URL during the 
initial login attempt, it does not attempt to reconnect or failover to the redundant 
BIPPA service. The agent must use the URL that points to the redundant BIPPA 
service.
If the CTI service is down, ACD and call control capabilities are disabled.