Configure Jumbo Frames on a StorMagic SvSAN VSA Logical NIC
Repeat the following steps on each SvSAN VSA to configure jumbo frames on VSA logical NICs.
1.  Log in to the vSphere Web Client and Click 
Hosts and Clusters.
2.  Select the data center at which the VSAs are deployed.
 Navigate to Manage > StorMagic > Manage VSAs.
3.  Select the VSA. A management URL will appear. Click the URL.
4.  A new tab will open connecting directly to the VSA. The default username is admin. Supply the password entered at VSA 
deployment.
5. Click 
Network and then select the network device you want to edit.
6.  From the 
Actions menu, choose Edit.
7.  Edit the MTU value to the desired size to match the rest of the environment network configuration (Figure 35). Then click 
Apply (Figure 36).
Figure 35.  Editing the Network Device
Figure 36.  Edited Devices