This message means that an internal power supply is not providing power. To receive this alert if power 
fails on the ME 3400G-12CS-DC switch with two power feeds, we recommend that you connect one feed 
to the left DC power terminal block and the other to the right DC power terminal block. (See the example 
in 
Figure 1
Connecting Separate Feeds to Each of the DC Power Terminal Blocks
If you want an alert if an external power supply fails, do not connect feeds to one terminal block and 
from there connect feeds to the second terminal block. (See the example in 
.) This configuration 
provides redundant power, and the switch continues to operate if one of the external power supplies fails. 
However, the software does not send a message to you that an internal power supply has failed.
Figure 2
Connecting Feeds from One Terminal Block to the Second Terminal Block