Cisco Cisco Aironet 1522 Lightweight Outdoor Mesh Access Point Guia Da Instalação
40
Cisco Aironet 1520 Series Outdoor Mesh Access Point Mounting Instructions
78-18269-04
Connecting a Fiber-Optic Cable to the Access Point
Step 3
Open the electrical joint compound (supplied), and apply a liberal amount over the metal surface where
the ground strap screw holes are located (see
the ground strap screw holes are located (see
).
Step 4
Connect the grounding lug to the access point grounding screw holes (see
) using the supplied
two Phillips head screws (M4 x10 mm) with lock washers. Tighten the grounding screw to
22 to 24 in. lbs (2.49 to 2.71 Nm).
22 to 24 in. lbs (2.49 to 2.71 Nm).
Step 5
If necessary, strip the other end of the ground wire, and connect it to a reliable earth ground such as a
grounding rod (see
grounding rod (see
), an appropriate grounding point on a metal streetlight pole that is grounded
(see
), or a grounded cable on a cable strand.
Connecting a Fiber-Optic Cable to the Access Point
The fiber-optic kit (GLC-FE-100BX-URGD=) enables the access point to support fiber-optic network
connections. The kit contains these parts:
connections. The kit contains these parts:
•
100BASE-BX10-U rugged SFP module
–
Single strand fiber bidirectional optical transceiver
–
1.3/1.5 micro-meter wavelength division multiplexing (WDM) function
–
125-Mb/s data rates
–
Single mode LC receptacle
•
Eight screws
•
Two small take-up reels
•
Two large take-up reels
•
One liquid tight adapter—accepts a cable diameter of 0.20 to 0.35 in. (0.51 to 0.89 cm)
Warning
Class 1 laser product. Statement 1008
Note
You need a customer supplied outdoor-rated fiber-optic cable with an LC connector. The cable diameter
must be 0.20 to 0.35 in. (0.52 to 0.89 cm) in diameter.
must be 0.20 to 0.35 in. (0.52 to 0.89 cm) in diameter.
To connect a fiber-optic cable to the access point, follow these steps:
Step 1
Ensure that all power sources have been disconnected from the access point.
Warning
This unit might have more than one power supply connection. All connections must be removed to
de-energize the unit. Statement 1028
de-energize the unit. Statement 1028
Note
If your access point contains a backup battery pack, you must depress the reset button for
10 seconds or more (see the
10 seconds or more (see the
).