Step 5
From the File Type drop-down box, choose Code.
Step 6
In the IP Address field, enter the IP address of the TFTP server.
Step 7
The default values of 10 retries and 6 seconds for the Maximum Retries and Timeout fields should work 
fine without any adjustment. However, you can change these values if desired. To do so, enter the 
maximum number of times that the TFTP server attempts to download the software in the Maximum 
Retries field and the amount of time (in seconds) that the TFTP server attempts to download the software 
in the Timeout field.
Step 8
In the File Path field, enter the directory path of the software.
Step 9
In the File Name field, enter the name of the software file (filename.aes).
Step 10
Click Download to download the software to the controller. A message appears indicating the status of 
the download.
Step 11
Repeat 
 to 
 to install the remaining file (either the 4.2.176.0 controller software or the 
Cisco Unified Wireless Network Controller Boot Software 4.2.112.0 ER.aes file).
Step 12
After the download is complete, click Reboot.
Step 13
If prompted to save your changes, click Save and Reboot.
Step 14
Click OK to confirm your decision to reboot the controller.
Step 15
If desired, reload your latest configuration file to the controller.
Step 16
To verify that the 4.2.176.0 controller software is installed on your controller, click Monitor on the 
controller GUI and look at the Software Version field under Controller Summary.
Step 17
To verify that the Cisco Unified Wireless Network Controller Boot Software 4.2.112.0 ER.aes file is 
installed on your controller, enter the show sysinfo command on the controller CLI and look at the 
Bootloader Version field. “N/A” appears if the ER.aes file is installed successfully. “Error” appears if 
the ER.aes file is not installed.
Note
You can use this command to verify the boot software version on all controllers except the 2106 
because the bootloader is not upgradable on the 2106 controller.
Installation Notes
This section contains important information to keep in mind when installing controllers and access 
points.
Warnings
Warning
This warning means danger. You are in a situation that could cause bodily injury. Before you work on 
any equipment, be aware of the hazards involved with electrical circuitry and be familiar with 
standard practices for preventing accidents.