Cisco Cisco Aironet 340 Ethernet Bridges Guia Do Utilizador

Página de 218
Setting Network Identifiers   6 - 5
The Flags column displays letters identifying the type of entry:
S: Entry is static (entered by operator)
N: Entry is an remote network route
H: Entry is a host route
The Use column indicates the number of packets that have been for-
warded using this table entry.
Setting up the Time Base (Configuration Time)
This menu lets you configure the bridge to query a network time server 
such that any logs its printed can reference the current date and time.
The time_server option sets the IP address or name of a unix time proto-
col server to be queried. The sntp_server option sets the IP address or 
name of an internet simple network time protocol server to be queried. 
You should configure only one type of server.
Since the time returned by the servers is based on Greenwich mean time 
you must use the Offset option to give the time difference in minutes 
(plus or minus) from GMT.
The Dst option selects whether your time zone uses daylight savings 
time.
                Configuration Time Menu
    Option              Value             Description
1 - Time_server   [ 149.023.165.080 ]   - Time protocol server   
2 - Sntp_server   [ 000.000.000.000 ]   - Network time server  
3 - Offset        [      -300       ]   - GMT offset in minutes  
4 - Dst           [       on        ]   - Use daylight savings time 
>_
Enter an option number or name, “=” main menu, <ESC> previous menu