Cisco Cisco Packet Data Gateway (PDG) Guia Da Instalação

Página de 195
ASR 5500 Hardware Platform Overview   
▀  Card Types 
 
 
▄  ASR 5500 Installation Guide 
22 
   
Front Cards 
The ASR 5500 supports two types of front-mounted cards: 
 
  
 
  
The crossbars that comprise the switching fabric are on the FSCs. The ASR 5500 supports multiple FSCs. Each FSC 
provides six physical fabric planes. When fully populated, there are 24 fabric planes in the system. A physical fabric 
plane provides full-mesh connectivity between all traffic sources. 
Fabric and Storage Card (FSC) 
The ASR 5500 chassis supports multiple FSCs in front facing slots of the chassis. 
The FSC features: 
 
Fabric cross-bars providing in aggregate: 
 
120 Gbps full-duplex fabric connection to each MIO/UMIO 
 
60 Gbps full-duplex fabric connection to each DPC/UDPC or DPC2/UDPC2 
 
FSC-200GB – Two 2.5" serial attached SCSI (SAS), 200GB solid state drives (SSDs) with a 6 Gbps SAS 
connection to each MIO/UMIO. The SSDs support a RAID 0 configuration on the card. 
–OR– 
 
FSC-400GB – One 2.5" serial attached SCSI (SAS), 400GB solid state drive (SSD) with a 6 Gbps SAS 
connection to each MIO/UMIO. The FSC-400GB is interchangeable with the FSC-200GB, as long as the 
StarOS release supports the non-RAID 0 configuration of the single 400GB drive. 
Every FSC adds to the available fabric bandwidth to each card. Each FSC connects to all MIO/UMIOs and data 
processing cards, with a varying number of links depending on the MIO/UMIO or data processing card slot. Three FSCs 
provide sufficient bandwidth while the fourth FSC supports redundancy. 
Important:
  Although four FSCs are required for redundancy, the system can operate with three FSCs in the 
presence of a fourth failed FSC. However, you must install four FSCs for normal operation. 
The ASR 5500 uses an array of solid state drives (SSDs) for short-term persistent storage. The RAID 5 configuration 
has each pair of drives on an FSC-200GB striped into a RAID 0 array; all the arrays are then grouped into a RAID 5 
array. The single SSD on the FCS-400GB does not support RAID 0 but participates in the RAID 5 array. 
Each FSC provides the storage for one quarter of the RAID 5 array in a four-FSC configuration. Data is striped across 
all four FSCs with each FSC providing parity data for the other three FSCs. The array is managed by the active 
MIO/UMIO. 
When equipped with six FSCs, four of the FSCs are active (switch fabric) and form the RAID 5 array (all their SSDs are 
active). FSC-5 and FSC-6 are active (switch fabric) with their SSDs in Standby mode. Their SSDs will only become 
active in the event of an array failure. 
Important:
  The SSDs are not field replaceable units (FRUs). If an SSD fails the FSC must be replaced.