Cisco Cisco Nexus 5010 Switch Guia Do Desenho
Design Guide
© 2010 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 31 of 38
Dual Active Detected
vPC Peer Link Status
---------------------------------------------------------------------
id Port Status Active vLANs
-- ---- ------ --------------------------------------------------
1 Po10 down -
vPC status
----------------------------------------------------------------------
id Port Status Consistency Reason Active vLANs
-- ---- ------ ----------- -------------------------- ------------
51 Po51 down success success -
The access switch uses the remaining link:
tc-nexus5k01# show port channel summary
--------------------------------------------------------------------------------
Group Port- Type Protocol Member Ports
Channel
--------------------------------------------------------------------------------
51 Po51(SU) Eth LACP Eth2/1(P) Eth2/2(D)
The peer-keepalive communication helps ensure that the loss of the peer-link path does not introduce any unwanted
flooding or split-subnet scenarios.
Figure 21 shows the failure scenario in the presence of a fabric extender. The vPC operational secondary shuts down
the vPC member port to host 1, which is directly attached to N5k01 and the vPC member port of host 2 connected to
Cisco Nexus 2000 Series Fabric Extender N2k01.