Cisco Cisco Packet Data Gateway (PDG) Guia Do Administrador
Switching CDRs
▀ Switching CDRs from GSS to HDD
▄ Cisco ASR 5x00 GTPP Interface Administration and Reference
410
Switching CDRs from GSS to HDD
This section describes how to switch CDRs from GSS to HDD with:
LRSN Enabled
To switch CDRs from GSS to HDD with LRSN enabled:
Important:
This configuration change must be undertaken in a maintenance window, when the load is minimum.
Step 1
Ensure that GSS is up and running, and that GGSN is able to deliver CDRs to GSS.
Start the changes from a known good state.
Step 2
Add the HDD configuration.
If configuring to the default GTPP group:
configure
gtpp single-source centralized-lrsn-creation
context <billing>
gtpp storage-server local file format <file_format_as_in_gss.cfg>
gtpp storage-server local file rotation volume mb 40
gtpp storage-server local file rotation cdr-count
<max_CDR_per_file_as_in_gss.cfg>
<max_CDR_per_file_as_in_gss.cfg>
gtpp storage-server local file rotation time-interval
<max_file_gen_period_as_in_gss.cfg>
<max_file_gen_period_as_in_gss.cfg>
gtpp dictionary <gtpp_dict_as_in_gss.cfg>
gtpp storage-server mode local
end
show configuration | grep gtpp
Important:
Note that
gtpp storage-server mode local
must be added at the end.
If configuring to a specific GTPP group:
configure